{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2025-24330 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-24330 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-24330 is a medium-severity path traversal vulnerability in Nokia Single RAN, published on 2 Jul 2025. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-24330 and fix it if it is affected.\n\nWhat it is: CVE-2025-24330 is a medium-severity path traversal vulnerability in Nokia Single RAN, published on 2 Jul 2025. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2025-24330 in the wild and no public exploit code.\n\nAffected product: Nokia Single RAN. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-24330/ (Markdown: https://insights.sbomify.com/CVE-2025-24330/index.md)","id":"CVE-2025-24330","markdown":"https://insights.sbomify.com/CVE-2025-24330/index.md","name":"CVE-2025-24330","record":{"aliases":["GHSA-jrhm-gh44-xj4m"],"analysis":{"component_type":"network_device","fix_type":"upgrade","impacts":["data_read","data_modify"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Nokia Single RAN","requires_auth":"high_privilege","summary":"Attackers can exploit path traversal in Nokia Single RAN baseband software via crafted SOAP messages to access or modify files.","user_interaction":"not_required","vuln_class":"path_traversal"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"Nokia","cpe":[],"cvss":{"score":6.4,"severity":"medium","source":"cisa-adp","vector":"CVSS:3.1/AV:A/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-22","name":"Improper Limitation of a Pathname to a Restricted Directory"}],"description":"Sending a crafted SOAP \"provision\" operation message PlanId field within the Mobile Network Operator (MNO) internal Radio Access Network (RAN) management network can cause path traversal issue in Nokia Single RAN baseband software with versions earlier than release 24R1-SR 1.0 MP. This issue has been corrected to release 24R1-SR 1.0 MP and later.\n\nBeginning with release 24R1-SR 1.0 MP, the OAM service software performed PlanId field input validations mitigate the reported path traversal issue.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"OAM service path traversal issue caused by a crafted SOAP message PlanId field within the RAN management network","id":"CVE-2025-24330","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"path_traversal","year":"2025"},"n_packages":0,"n_references":1,"next":{"headline":"Nokia Single RAN baseband OAM service extensive capabilities","id":"CVE-2025-24331"},"packages":[],"prev":{"headline":"OAM service path traversal issue caused by a crafted SOAP message archive field within the RAN management network","id":"CVE-2025-24329"},"products":["Nokia Single RAN"],"published":"2025-07-02","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-07-02","vendors":["Nokia"]},"summary":"Attackers can exploit path traversal in Nokia Single RAN baseband software via crafted SOAP messages to access or modify files.","url":"https://insights.sbomify.com/CVE-2025-24330/"}