{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2025-24333 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-24333 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-24333 is a medium-severity command injection vulnerability in Nokia Single RAN, published on 2 Jul 2025. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-24333 and fix it if it is affected.\n\nWhat it is: CVE-2025-24333 is a medium-severity command injection vulnerability in Nokia Single RAN, published on 2 Jul 2025. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2025-24333 in the wild and no public exploit code.\n\nAffected product: Nokia Single RAN. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-24333/ (Markdown: https://insights.sbomify.com/CVE-2025-24333/index.md)","id":"CVE-2025-24333","markdown":"https://insights.sbomify.com/CVE-2025-24333/index.md","name":"CVE-2025-24333","record":{"aliases":["GHSA-w3f7-726g-4f2w"],"analysis":{"component_type":"network_device","fix_type":"upgrade","impacts":["code_execution"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Nokia Single RAN","requires_auth":"high_privilege","summary":"Authenticated administrators can inject arbitrary commands into the baseband OAM service via special characters in a configuration file, leading to code execution.","user_interaction":"not_required","vuln_class":"command_injection"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"Nokia","cpe":[],"cvss":{"score":6.4,"severity":"medium","source":"cisa-adp","vector":"CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-77","name":"Improper Neutralization of Special Elements used in a Command"}],"description":"Nokia Single RAN baseband software earlier than 24R1-SR 1.0 MP contains administrative shell input validation fault, which authenticated admin user can, in theory, potentially use for injecting arbitrary commands for unprivileged baseband OAM service process execution via special characters added to baseband internal COMA_config.xml file.\n\nThis issue has been corrected starting from release 24R1-SR 1.0 MP and later, by adding proper input validation to OAM service process which prevents injecting special characters via baseband internal COMA_config.xml file.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Administrative user shell input validation fault","id":"CVE-2025-24333","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"command_injection","year":"2025"},"n_packages":0,"n_references":1,"next":{"headline":"The Nokia Single RAN baseband reveals its software version through the MNO internal RAN management network","id":"CVE-2025-24334"},"packages":[],"prev":{"headline":"Authenticated admin user can connect baseband internally from one board to another without needing to re-authentication","id":"CVE-2025-24332"},"products":["Nokia Single RAN"],"published":"2025-07-02","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-07-02","vendors":["Nokia"]},"summary":"Authenticated administrators can inject arbitrary commands into the baseband OAM service via special characters in a configuration file, leading to code execution.","url":"https://insights.sbomify.com/CVE-2025-24333/"}