{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2025-2441 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-2441 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-2441 is a medium-severity vulnerability in Schneider Electric Trio Q Licensed Data Radio, published on 9 Apr 2025. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-2441 and fix it if it is affected.\n\nWhat it is: CVE-2025-2441 is a medium-severity vulnerability in Schneider Electric Trio Q Licensed Data Radio, published on 9 Apr 2025. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2025-2441 in the wild and no public exploit code.\n\nAffected product: Schneider Electric Trio Q Licensed Data Radio. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-2441/ (Markdown: https://insights.sbomify.com/CVE-2025-2441/index.md)","id":"CVE-2025-2441","markdown":"https://insights.sbomify.com/CVE-2025-2441/index.md","name":"CVE-2025-2441","record":{"aliases":["GHSA-m2c9-v8xf-797h"],"analysis":{"component_type":"iot_embedded","fix_type":"patch","impacts":["data_read"],"network_reachable":"adjacent_or_local","non_default_config":true,"product_category":"Licensed Data Radio","requires_auth":"none","summary":"A malicious user with physical access can reset the radio to factory defaults, causing insecure initialization and potential loss of confidentiality.","user_interaction":"not_required","vuln_class":"misconfiguration"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"schneider","cpe":[],"cvss":{"score":4.1,"severity":"medium","source":"cna","vector":"CVSS:4.0/AV:P/AC:L/AT:P/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-1188","name":"Initialization of a Resource with an Insecure Default"}],"description":"CWE-1188: Initialization of a Resource with an Insecure Default vulnerability exists that could lead to loss of\nconfidentiality when a malicious user, having physical access, sets the radio in factory default mode where the\nproduct does not correctly initialize all data.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Misconfiguration in Trio Q Licensed Data Radio","id":"CVE-2025-2441","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"misconfiguration","year":"2025"},"n_packages":0,"n_references":1,"next":{"headline":"Misconfiguration in Trio Q Licensed Data Radio","id":"CVE-2025-2442"},"packages":[],"prev":{"headline":"Information disclosure in Trio Q Licensed Data Radio","id":"CVE-2025-2440"},"products":["Trio Q Licensed Data Radio"],"published":"2025-04-09","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-04-09","vendors":["Schneider Electric"]},"summary":"A malicious user with physical access can reset the radio to factory defaults, causing insecure initialization and potential loss of confidentiality.","url":"https://insights.sbomify.com/CVE-2025-2441/"}