{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2025-24481 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-24481 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-24481 is a high-severity vulnerability in Rockwell Automation FactoryTalk® View Site Edition, published on 28 Jan 2025. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-24481 and fix it if it is affected.\n\nWhat it is: CVE-2025-24481 is a high-severity vulnerability in Rockwell Automation FactoryTalk® View Site Edition, published on 28 Jan 2025. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2025-24481 in the wild and no public exploit code.\n\nAffected product: Rockwell Automation FactoryTalk® View Site Edition. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-24481/ (Markdown: https://insights.sbomify.com/CVE-2025-24481/index.md)","id":"CVE-2025-24481","markdown":"https://insights.sbomify.com/CVE-2025-24481/index.md","name":"CVE-2025-24481","record":{"aliases":["GHSA-fv95-67f8-c94p"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["data_read","security_bypass"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Industrial HMI software","requires_auth":"none","summary":"Incorrect permissions on the remote debugger port allow unauthenticated attackers to access system configuration in FactoryTalk View Site Edition.","user_interaction":"not_required","vuln_class":"misconfiguration"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"Rockwell","cpe":[],"cvss":{"score":7,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:H/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-732","name":"Incorrect Permission Assignment for Critical Resource"}],"description":"An Incorrect Permission Assignment Vulnerability exists in the product and version listed above. The vulnerability is due to incorrect permissions being assigned to the remote debugger port and can allow for unauthenticated access to the system configuration.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"FactoryTalk® View Site Edition - Incorrect Permission Assignment","id":"CVE-2025-24481","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"misconfiguration","year":"2025"},"n_packages":0,"n_references":1,"next":{"headline":"FactoryTalk® View Site Edition - Local Code Injection","id":"CVE-2025-24482"},"packages":[],"prev":{"headline":"FactoryTalk® View Machine Editon - Remote Code Execution","id":"CVE-2025-24480"},"products":["FactoryTalk® View Site Edition"],"published":"2025-01-28","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-02-12","vendors":["Rockwell Automation"]},"summary":"Incorrect permissions on the remote debugger port allow unauthenticated attackers to access system configuration in FactoryTalk View Site Edition.","url":"https://insights.sbomify.com/CVE-2025-24481/"}