{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2025-24499 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-24499 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-24499 is a high-severity command injection vulnerability in Siemens SCALANCE WAB762-1, published on 11 Feb 2025. An attacker needs administrator access to exploit it, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-24499 and fix it if it is affected.\n\nWhat it is: CVE-2025-24499 is a high-severity command injection vulnerability in Siemens SCALANCE WAB762-1, published on 11 Feb 2025. An attacker needs administrator access to exploit it, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2025-24499 in the wild and no public exploit code.\n\nAffected product: Siemens SCALANCE WAB762-1. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-24499/ (Markdown: https://insights.sbomify.com/CVE-2025-24499/index.md)","id":"CVE-2025-24499","markdown":"https://insights.sbomify.com/CVE-2025-24499/index.md","name":"CVE-2025-24499","record":{"aliases":["GHSA-9hqf-2957-q2jh"],"analysis":{"component_type":"network_device","fix_type":"upgrade","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"Siemens SCALANCE wireless","requires_auth":"high_privilege","summary":"An authenticated remote attacker can execute arbitrary shell commands on Siemens SCALANCE wireless devices due to improper input validation in configuration files.","user_interaction":"not_required","vuln_class":"command_injection"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[],"cvss":{"score":7.5,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-20","name":"Improper Input Validation"}],"description":"A vulnerability has been identified in SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0) (All versions \u003c V3.0.0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions \u003c V3.0.0), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0) (All versions \u003c V3.0.0), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0) (All versions \u003c V3.0.0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0) (All versions \u003c V3.0.0), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0) (All versions \u003c V3.0.0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) (All versions \u003c V3.0.0), SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0) (All versions \u003c V3.0.0), SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0) (All versions \u003c V3.0.0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) (All versions \u003c V3.0.0), SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0) (All versions \u003c V3.0.0), SCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0) (All versions \u003c V3.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) (All versions \u003c V3.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) (All versions \u003c V3.0.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0) (All versions \u003c V3.0.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0) (All versions \u003c V3.0.0), SCALANCE WUM766-1 (6GK5766-1GE00-3DA0) (All versions \u003c V3.0.0), SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0) (All versions \u003c V3.0.0), SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0) (All versions \u003c V3.0.0). Affected devices do not properly validate input while loading the configuration files. This could allow an authenticated remote attacker to execute arbitrary shell commands on the device.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Command injection in SCALANCE WAB762-1","id":"CVE-2025-24499","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"command_injection","year":"2025"},"n_packages":0,"n_references":1,"next":{"headline":"Missing authorization in Symantec Privileged Access Management","id":"CVE-2025-24500"},"packages":[],"prev":{"headline":"BIG-IP PEM vulnerability","id":"CVE-2025-24497"},"products":["SCALANCE WAB762-1","SCALANCE WAM763-1","SCALANCE WAM763-1 (ME)","SCALANCE WAM763-1 (US)","SCALANCE WAM766-1","SCALANCE WAM766-1 (ME)","SCALANCE WAM766-1 (US)","SCALANCE WAM766-1 EEC","SCALANCE WAM766-1 EEC (ME)","SCALANCE WAM766-1 EEC (US)","SCALANCE WUB762-1","SCALANCE WUB762-1 iFeatures","SCALANCE WUM763-1","SCALANCE WUM763-1 (US)","SCALANCE WUM766-1","SCALANCE WUM766-1 (ME)","SCALANCE WUM766-1 (USA)"],"published":"2025-02-11","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-02-12","vendors":["Siemens"]},"summary":"An authenticated remote attacker can execute arbitrary shell commands on Siemens SCALANCE wireless devices due to improper input validation in configuration files.","url":"https://insights.sbomify.com/CVE-2025-24499/"}