{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2025-24532 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-24532 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-24532 is a medium-severity missing authorization vulnerability in Siemens SCALANCE WAB762-1, published on 11 Feb 2025. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-24532 and fix it if it is affected.\n\nWhat it is: CVE-2025-24532 is a medium-severity missing authorization vulnerability in Siemens SCALANCE WAB762-1, published on 11 Feb 2025. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2025-24532 in the wild and no public exploit code.\n\nAffected product: Siemens SCALANCE WAB762-1. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-24532/ (Markdown: https://insights.sbomify.com/CVE-2025-24532/index.md)","id":"CVE-2025-24532","markdown":"https://insights.sbomify.com/CVE-2025-24532/index.md","name":"CVE-2025-24532","record":{"aliases":["GHSA-7hh3-mrx6-fgwq"],"analysis":{"component_type":"network_device","fix_type":"upgrade","impacts":["data_modify"],"network_reachable":"yes","non_default_config":false,"product_category":"Siemens SCALANCE wireless","requires_auth":"low_privilege","summary":"An attacker with user role can modify SNMPv3 View Type due to incorrect authorization in Siemens SCALANCE wireless devices.","user_interaction":"not_required","vuln_class":"missing_authorization"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[],"cvss":{"score":5.3,"severity":"medium","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-284","name":"Improper Access Control"}],"description":"A vulnerability has been identified in SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0) (All versions \u003c V3.0.0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions \u003c V3.0.0), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0) (All versions \u003c V3.0.0), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0) (All versions \u003c V3.0.0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0) (All versions \u003c V3.0.0), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0) (All versions \u003c V3.0.0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) (All versions \u003c V3.0.0), SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0) (All versions \u003c V3.0.0), SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0) (All versions \u003c V3.0.0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) (All versions \u003c V3.0.0), SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0) (All versions \u003c V3.0.0), SCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0) (All versions \u003c V3.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) (All versions \u003c V3.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) (All versions \u003c V3.0.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0) (All versions \u003c V3.0.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0) (All versions \u003c V3.0.0), SCALANCE WUM766-1 (6GK5766-1GE00-3DA0) (All versions \u003c V3.0.0), SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0) (All versions \u003c V3.0.0), SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0) (All versions \u003c V3.0.0). Affected devices with role `user` is affected by incorrect authorization in SNMPv3 View configuration. This could allow an attacker to change the View Type of SNMPv3 Views.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Missing authorization in SCALANCE WAB762-1","id":"CVE-2025-24532","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"missing_authorization","year":"2025"},"n_packages":0,"n_references":1,"next":{"headline":"WordPress MetaSlider plugin \u003c= 3.92.0 - Cross Site Request Forgery (CSRF) vulnerability","id":"CVE-2025-24533"},"packages":[],"prev":{"headline":"Auth bypass in pam pkcs11","id":"CVE-2025-24531"},"products":["SCALANCE WAB762-1","SCALANCE WAM763-1","SCALANCE WAM763-1 (ME)","SCALANCE WAM763-1 (US)","SCALANCE WAM766-1","SCALANCE WAM766-1 (ME)","SCALANCE WAM766-1 (US)","SCALANCE WAM766-1 EEC","SCALANCE WAM766-1 EEC (ME)","SCALANCE WAM766-1 EEC (US)","SCALANCE WUB762-1","SCALANCE WUB762-1 iFeatures","SCALANCE WUM763-1","SCALANCE WUM763-1 (US)","SCALANCE WUM766-1","SCALANCE WUM766-1 (ME)","SCALANCE WUM766-1 (USA)"],"published":"2025-02-11","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-02-12","vendors":["Siemens"]},"summary":"An attacker with user role can modify SNMPv3 View Type due to incorrect authorization in Siemens SCALANCE wireless devices.","url":"https://insights.sbomify.com/CVE-2025-24532/"}