{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2025-24836 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-24836 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-24836 is a medium-severity denial of service vulnerability in Qardio Heart Health Android Mobile Application, published on 13 Feb 2025. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-24836 and fix it if it is affected.\n\nWhat it is: CVE-2025-24836 is a medium-severity denial of service vulnerability in Qardio Heart Health Android Mobile Application, published on 13 Feb 2025. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2025-24836 in the wild and no public exploit code.\n\nAffected product: Qardio Heart Health Android Mobile Application. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-24836/ (Markdown: https://insights.sbomify.com/CVE-2025-24836/index.md)","id":"CVE-2025-24836","markdown":"https://insights.sbomify.com/CVE-2025-24836/index.md","name":"CVE-2025-24836","record":{"aliases":["GHSA-pvvp-cjfg-4jv4"],"analysis":{"component_type":"iot_embedded","fix_type":"no_fix_stated","impacts":["denial_of_service"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Qardio heart monitor","requires_auth":"none","summary":"An attacker can cause a denial of service on Qardio heart monitors by flooding them with Bluetooth commands, preventing clinical readings.","user_interaction":"not_required","vuln_class":"denial_of_service"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[],"cvss":{"score":6.1,"severity":"medium","source":"cna","vector":"CVSS:4.0/AV:A/AC:H/AT:N/PR:N/UI:N/VC:L/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-248","name":"Uncaught Exception"}],"description":"With a specially crafted Python script, an attacker could send \ncontinuous startMeasurement commands over an unencrypted Bluetooth \nconnection to the affected device. This would prevent the device from \nconnecting to a clinician's app to take patient readings and ostensibly \nflood it with requests, resulting in a denial-of-service condition.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Qardio Heart Health IOS and Android Application and QardioARM A100 Uncaught Exception","id":"CVE-2025-24836","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"denial_of_service","year":"2025"},"n_packages":0,"n_references":2,"next":{"headline":"This CVE ID has been rejected or withdrawn by its CVE Numbering Authority because it is Unused","id":"CVE-2025-24837"},"packages":[],"prev":{"headline":"Security feature bypass in Intel(R) Arc(TM) B-Series graphics","id":"CVE-2025-24835"},"products":["Heart Health Android Mobile Application","Heart Health IOS Mobile Application","QardioARM"],"published":"2025-02-13","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-02-14","vendors":["Qardio"]},"summary":"An attacker can cause a denial of service on Qardio heart monitors by flooding them with Bluetooth commands, preventing clinical readings.","url":"https://insights.sbomify.com/CVE-2025-24836/"}