{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2025-25280 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-25280 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-25280 is a medium-severity memory corruption vulnerability in Century Systems Co., Ltd. FutureNet AS-210/U4, published on 3 Mar 2025. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-25280 and fix it if it is affected.\n\nWhat it is: CVE-2025-25280 is a medium-severity memory corruption vulnerability in Century Systems Co., Ltd. FutureNet AS-210/U4, published on 3 Mar 2025. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2025-25280 in the wild and no public exploit code.\n\nAffected product: Century Systems Co., Ltd. FutureNet AS-210/U4. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-25280/ (Markdown: https://insights.sbomify.com/CVE-2025-25280/index.md)","id":"CVE-2025-25280","markdown":"https://insights.sbomify.com/CVE-2025-25280/index.md","name":"CVE-2025-25280","record":{"aliases":["GHSA-vr9j-f779-6jqx"],"analysis":{"component_type":"network_device","fix_type":"no_fix_stated","impacts":["denial_of_service"],"network_reachable":"yes","non_default_config":false,"product_category":"Industrial router","requires_auth":"none","summary":"A remote unauthenticated attacker can reboot Century Systems industrial routers and protocol converters by sending a specially crafted request.","user_interaction":"not_required","vuln_class":"memory_corruption"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"jpcert","cpe":[],"cvss":{"score":5.3,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L","version":"3.1"},"cwes":[{"id":"CWE-120","name":"Buffer Copy without Checking Size of Input"}],"description":"Buffer overflow vulnerability exists in FutureNet AS series (Industrial Routers) and FA series (Protocol Conversion Machine) provided by Century Systems Co., Ltd. If this vulnerability is exploited, a remote unauthenticated attacker may reboot the device by sending a specially crafted request.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Memory corruption in FutureNet AS-210/U4","id":"CVE-2025-25280","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"memory_corruption","year":"2025"},"n_packages":0,"n_references":2,"next":{"headline":"Outback Power Mojave Inverter Exposure of Sensitive Information to an Unauthorized Actor","id":"CVE-2025-25281"},"packages":[],"prev":{"headline":"Arbitrary file read in Mattermost Boards via import \u0026 export board archive","id":"CVE-2025-25279"},"products":["FutureNet AS-210/U4","FutureNet AS-250/F-KO","FutureNet AS-250/F-SC","FutureNet AS-250/KL","FutureNet AS-250/KL Rev2","FutureNet AS-250/L","FutureNet AS-250/NL","FutureNet AS-250/S","FutureNet AS-M250/KL","FutureNet AS-M250/L","FutureNet AS-M250/NL","FutureNet AS-P250/KL","FutureNet AS-P250/NL","FutureNet FA-210","FutureNet FA-215"],"published":"2025-03-03","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-03-03","vendors":["Century Systems Co., Ltd."]},"summary":"A remote unauthenticated attacker can reboot Century Systems industrial routers and protocol converters by sending a specially crafted request.","url":"https://insights.sbomify.com/CVE-2025-25280/"}