{"answers":{"affected":"","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2025-26793 exists.","fix":"No fix has been published for CVE-2025-26793 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-26793 is a critical vulnerability in Hirsch Enterphone MESH, published on 15 Feb 2025. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-26793 and fix it if it is affected.\n\nWhat it is: CVE-2025-26793 is a critical vulnerability in Hirsch Enterphone MESH, published on 15 Feb 2025. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2025-26793 exists.\n\nAffected product: Hirsch Enterphone MESH. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-26793/ (Markdown: https://insights.sbomify.com/CVE-2025-26793/index.md)","id":"CVE-2025-26793","markdown":"https://insights.sbomify.com/CVE-2025-26793/index.md","name":"CVE-2025-26793","record":{"aliases":["GHSA-x8v9-7r66-c92w"],"analysis":{"component_type":"iot_embedded","fix_type":"configuration_change","impacts":["data_read","security_bypass"],"network_reachable":"yes","non_default_config":false,"product_category":"Apartment intercom system","requires_auth":"none","summary":"Attackers can use default credentials to access the Web GUI of Hirsch Enterphone MESH systems, exposing resident PII and building controls.","user_interaction":"not_required","vuln_class":"hardcoded_credentials"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"mitre","cpe":[],"cvss":{"score":10,"severity":"critical","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N/MSI:S/S:P","version":"4.0"},"cwes":[{"id":"CWE-1393","name":"Use of Default Password"}],"description":"The Web GUI configuration panel of Hirsch (formerly Identiv and Viscount) Enterphone MESH through 2024 ships with default credentials (username freedom, password viscount). The administrator is not prompted to change these credentials on initial configuration, and changing the credentials requires many steps. Attackers can use the credentials over the Internet via mesh.webadmin.MESHAdminServlet to gain access to dozens of Canadian and U.S. apartment buildings and obtain building residents' PII. NOTE: the Supplier's perspective is that the \"vulnerable systems are not following manufacturers' recommendations to change the default password.\"","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":1,"refs":[{"date":null,"kind":"nuclei","ref":"http/cves/2025/CVE-2025-26793.yaml","stars":null,"title":"FREEDOM Administration - Default Login"}],"tier":"weaponised"},"has_fix":null,"headline":"Hardcoded credentials in Enterphone MESH","id":"CVE-2025-26793","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"hardcoded_credentials","year":"2025"},"n_packages":0,"n_references":3,"next":{"headline":"SQL injection in Exim","id":"CVE-2025-26794"},"packages":[],"prev":{"headline":"DOMPurify allows Cross-site Scripting (XSS)","id":"CVE-2025-26791"},"products":["Enterphone MESH"],"published":"2025-02-15","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"},{"class":"attribution","licence":"MIT","name":"Nuclei templates"}],"ssvc":{"automatable":"yes","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-02-24","vendors":["Hirsch"]},"summary":"Attackers can use default credentials to access the Web GUI of Hirsch Enterphone MESH systems, exposing resident PII and building controls.","url":"https://insights.sbomify.com/CVE-2025-26793/"}