{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2025-27397 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-27397 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-27397 is a medium-severity path traversal vulnerability in Siemens SCALANCE LPE9403, published on 11 Mar 2025. An attacker needs administrator access to exploit it, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-27397 and fix it if it is affected.\n\nWhat it is: CVE-2025-27397 is a medium-severity path traversal vulnerability in Siemens SCALANCE LPE9403, published on 11 Mar 2025. An attacker needs administrator access to exploit it, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2025-27397 in the wild and no public exploit code.\n\nAffected product: Siemens SCALANCE LPE9403. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-27397/ (Markdown: https://insights.sbomify.com/CVE-2025-27397/index.md)","id":"CVE-2025-27397","markdown":"https://insights.sbomify.com/CVE-2025-27397/index.md","name":"CVE-2025-27397","record":{"aliases":["GHSA-gqcm-6vpg-xm6w"],"analysis":{"component_type":"network_device","fix_type":"upgrade","impacts":["data_read","data_modify"],"network_reachable":"yes","non_default_config":false,"product_category":"Siemens SCALANCE LPE9403","requires_auth":"high_privilege","summary":"An authenticated privileged attacker can read and write arbitrary files on Siemens SCALANCE LPE9403 devices via path traversal in log handling.","user_interaction":"not_required","vuln_class":"path_traversal"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[{"product":"scalance_lpe9403_firmware","vendor":"siemens"}],"cvss":{"score":5.1,"severity":"medium","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-22","name":"Improper Limitation of a Pathname to a Restricted Directory"}],"description":"A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions \u003c V4.0). Affected devices do not properly limit user controlled paths to which logs are written and from where they are read.\r\nThis could allow an authenticated highly-privileged remote attacker to read and write arbitrary files in the filesystem, if and only if the malicious path ends with 'log' .","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Path traversal in SCALANCE LPE9403","id":"CVE-2025-27397","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"path_traversal","year":"2025"},"n_packages":0,"n_references":1,"next":{"headline":"Command injection in SCALANCE LPE9403","id":"CVE-2025-27398"},"packages":[],"prev":{"headline":"Privilege escalation in SCALANCE LPE9403","id":"CVE-2025-27396"},"products":["SCALANCE LPE9403"],"published":"2025-03-11","related":[{"cvss_score":9.9,"headline":"Command injection in SCALANCE LPE9403","id":"CVE-2023-27407","kev_date_added":null,"published":"2023-05-09"},{"cvss_score":8.7,"headline":"Privilege escalation in SCALANCE LPE9403","id":"CVE-2025-27396","kev_date_added":null,"published":"2025-03-11"},{"cvss_score":8.6,"headline":"Command injection in SCALANCE LPE9403","id":"CVE-2025-27392","kev_date_added":null,"published":"2025-03-11"},{"cvss_score":8.6,"headline":"Command injection in SCALANCE LPE9403","id":"CVE-2025-27393","kev_date_added":null,"published":"2025-03-11"},{"cvss_score":8.6,"headline":"Command injection in SCALANCE LPE9403","id":"CVE-2025-27394","kev_date_added":null,"published":"2025-03-11"},{"cvss_score":8.6,"headline":"Path traversal in SCALANCE LPE9403","id":"CVE-2025-27395","kev_date_added":null,"published":"2025-03-11"},{"cvss_score":8.5,"headline":"Missing authorization in SCALANCE LPE9403","id":"CVE-2025-40574","kev_date_added":null,"published":"2025-05-13"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-03-11","vendors":["Siemens"]},"summary":"An authenticated privileged attacker can read and write arbitrary files on Siemens SCALANCE LPE9403 devices via path traversal in log handling.","url":"https://insights.sbomify.com/CVE-2025-27397/"}