{"answers":{"affected":"It affects 2 products.","exploited":"There is no known exploitation of CVE-2025-27494 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-27494 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-27494 is a critical command injection vulnerability in Siemens SiPass integrated AC5102 (ACC-G2), published on 11 Mar 2025. An attacker needs administrator access to exploit it, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-27494 and fix it if it is affected.\n\nWhat it is: CVE-2025-27494 is a critical command injection vulnerability in Siemens SiPass integrated AC5102 (ACC-G2), published on 11 Mar 2025. An attacker needs administrator access to exploit it, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2025-27494 in the wild and no public exploit code.\n\nAffected product: Siemens SiPass integrated AC5102 (ACC-G2). No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-27494/ (Markdown: https://insights.sbomify.com/CVE-2025-27494/index.md)","id":"CVE-2025-27494","markdown":"https://insights.sbomify.com/CVE-2025-27494/index.md","name":"CVE-2025-27494","record":{"aliases":["GHSA-m2p6-m8pm-fvcc"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["code_execution","privilege_escalation"],"network_reachable":"yes","non_default_config":false,"product_category":"Siemens access control","requires_auth":"high_privilege","summary":"Authenticated administrators can inject commands via the REST API to execute arbitrary code with root privileges on Siemens access control devices.","user_interaction":"not_required","vuln_class":"command_injection"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[{"product":"sipass_integrated_ac5102_\\(acc-g2\\)_firmware","vendor":"siemens"},{"product":"sipass_integrated_acc-ap_firmware","vendor":"siemens"}],"cvss":{"score":9.4,"severity":"critical","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H","version":"4.0"},"cwes":[{"id":"CWE-20","name":"Improper Input Validation"}],"description":"A vulnerability has been identified in SiPass integrated AC5102 (ACC-G2) (All versions \u003c V6.4.9), SiPass integrated ACC-AP (All versions \u003c V6.4.9). Affected devices improperly sanitize input for the pubkey endpoint of the REST API. This could allow an authenticated remote administrator to escalate privileges by injecting arbitrary commands that are executed with root privileges.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Command injection in SiPass integrated AC5102 (ACC-G2)","id":"CVE-2025-27494","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"command_injection","year":"2025"},"n_packages":0,"n_references":1,"next":{"headline":"SQL injection in TeleControl Server Basic","id":"CVE-2025-27495"},"packages":[],"prev":{"headline":"Command injection in SiPass integrated AC5102 (ACC-G2)","id":"CVE-2025-27493"},"products":["SiPass integrated AC5102 (ACC-G2)","SiPass integrated ACC-AP"],"published":"2025-03-11","related":[{"cvss_score":9.3,"headline":"Command injection in SiPass integrated AC5102 (ACC-G2)","id":"CVE-2025-27493","kev_date_added":null,"published":"2025-03-11"},{"cvss_score":7.8,"headline":"Command injection in SiPass integrated AC5102 (ACC-G2)","id":"CVE-2022-31808","kev_date_added":null,"published":"2023-02-14"},{"cvss_score":5.9,"headline":"Other in Building X - Security Manager Edge Controller (ACC-AP)","id":"CVE-2022-31807","kev_date_added":null,"published":"2025-05-23"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-03-11","vendors":["Siemens"]},"summary":"Authenticated administrators can inject commands via the REST API to execute arbitrary code with root privileges on Siemens access control devices.","url":"https://insights.sbomify.com/CVE-2025-27494/"}