{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2025-28361 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-28361 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-28361 is a high-severity vulnerability in n/a, published on 26 Mar 2025. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-28361 and fix it if it is affected.\n\nWhat it is: CVE-2025-28361 is a high-severity vulnerability in n/a, published on 26 Mar 2025. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2025-28361 in the wild and no public exploit code.\n\nAffected product: n/a. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-28361/ (Markdown: https://insights.sbomify.com/CVE-2025-28361/index.md)","id":"CVE-2025-28361","markdown":"https://insights.sbomify.com/CVE-2025-28361/index.md","name":"CVE-2025-28361","record":{"aliases":["GHSA-77cg-5fj2-g4fx"],"analysis":{"component_type":"network_device","fix_type":"no_fix_stated","impacts":["data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"Telesquare router","requires_auth":"none","summary":"A remote attacker can exploit a stack overflow in the systemutil.cgi component to obtain sensitive information from the device.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"mitre","cpe":[{"product":"tlr-2005ksh_firmware","vendor":"telesquare"}],"cvss":{"score":7.5,"severity":"high","source":"cisa-adp","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","version":"3.1"},"cwes":[{"id":"CWE-120","name":"Buffer Copy without Checking Size of Input"}],"description":"Unauthorized stack overflow vulnerability in Telesquare TLR-2005KSH v.1.1.4 allows a remote attacker to obtain sensitive information via the systemutil.cgi component.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Information disclosure in n/a","id":"CVE-2025-28361","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2025"},"n_packages":0,"n_references":1,"next":{"headline":"Path traversal in n/a","id":"CVE-2025-28367"},"packages":[],"prev":{"headline":"Other in n/a","id":"CVE-2025-28357"},"products":["n/a"],"published":"2025-03-26","related":[{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2025-26002","kev_date_added":null,"published":"2025-03-26"},{"cvss_score":9.8,"headline":"Command injection in n/a","id":"CVE-2025-26003","kev_date_added":null,"published":"2025-03-26"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2025-26004","kev_date_added":null,"published":"2025-03-26"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2025-26005","kev_date_added":null,"published":"2025-03-26"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2025-26006","kev_date_added":null,"published":"2025-03-26"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2025-26007","kev_date_added":null,"published":"2025-03-26"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2025-26008","kev_date_added":null,"published":"2025-03-26"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-03-27","vendors":["n/a"]},"summary":"A remote attacker can exploit a stack overflow in the systemutil.cgi component to obtain sensitive information from the device.","url":"https://insights.sbomify.com/CVE-2025-28361/"}