{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2025-2875 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-2875 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-2875 is a high-severity server-side request forgery vulnerability in Schneider Electric Modicon Controllers M241 / M251, published on 14 May 2025. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-2875 and fix it if it is affected.\n\nWhat it is: CVE-2025-2875 is a high-severity server-side request forgery vulnerability in Schneider Electric Modicon Controllers M241 / M251, published on 14 May 2025. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2025-2875 in the wild and no public exploit code.\n\nAffected product: Schneider Electric Modicon Controllers M241 / M251. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-2875/ (Markdown: https://insights.sbomify.com/CVE-2025-2875/index.md)","id":"CVE-2025-2875","markdown":"https://insights.sbomify.com/CVE-2025-2875/index.md","name":"CVE-2025-2875","record":{"aliases":["GHSA-cjwm-r7h6-vpg7"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"Modicon PLC","requires_auth":"none","summary":"Unauthenticated attackers can manipulate the controller's webserver URL to access internal resources, leading to information disclosure.","user_interaction":"not_required","vuln_class":"ssrf"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"schneider","cpe":[],"cvss":{"score":8.7,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-610","name":"Externally Controlled Reference to a Resource in Another Sphere"}],"description":"CWE-610: Externally Controlled Reference to a Resource in Another Sphere vulnerability exists that could\ncause a loss of confidentiality when an unauthenticated attacker manipulates controller’s webserver URL to\naccess resources.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Server-side request forgery in Modicon Controllers M241 / M251","id":"CVE-2025-2875","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"ssrf","year":"2025"},"n_packages":0,"n_references":1,"next":{"headline":"Missing authorization in MelaPress Login Security","id":"CVE-2025-2876"},"packages":[],"prev":{"headline":"User Submitted Posts \u003c= 20241026 - Authenticated (Admin+) Stored Cross-Site Scripting","id":"CVE-2025-2874"},"products":["Modicon Controllers M241 / M251","Modicon Controllers M258 / LMC058"],"published":"2025-05-14","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-05-14","vendors":["Schneider Electric"]},"summary":"Unauthenticated attackers can manipulate the controller's webserver URL to access internal resources, leading to information disclosure.","url":"https://insights.sbomify.com/CVE-2025-2875/"}