{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2025-29757 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-29757 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-29757 is a critical missing authorization vulnerability in https://oss.growatt.com, published on 19 Jul 2025. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-29757 and fix it if it is affected.\n\nWhat it is: CVE-2025-29757 is a critical missing authorization vulnerability in https://oss.growatt.com, published on 19 Jul 2025. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2025-29757 in the wild and no public exploit code.\n\nAffected product: https://oss.growatt.com. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-29757/ (Markdown: https://insights.sbomify.com/CVE-2025-29757/index.md)","id":"CVE-2025-29757","markdown":"https://insights.sbomify.com/CVE-2025-29757/index.md","name":"CVE-2025-29757","record":{"aliases":["GHSA-j8w3-hxm2-cw7f"],"analysis":{"component_type":"cloud_service","fix_type":"no_fix_stated","impacts":["data_modify","privilege_escalation"],"network_reachable":"yes","non_default_config":false,"product_category":"Growatt cloud service","requires_auth":"low_privilege","summary":"An attacker with a valid account can transfer any plant to their own account due to incorrect authorization checks in the Growatt cloud service.","user_interaction":"not_required","vuln_class":"missing_authorization"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"DIVD","cpe":[],"cvss":{"score":9.4,"severity":"critical","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:N/SC:H/SI:H/SA:H/S:P/V:C","version":"4.0"},"cwes":[{"id":"CWE-863","name":"Incorrect Authorization"}],"description":"An incorrect authorisation check in the the 'plant transfer' function of the Growatt cloud service allowed a malicous attacker with a valid account to transfer any plant into his/her account.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Missing authorization in https://oss.growatt.com","id":"CVE-2025-29757","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"missing_authorization","year":"2025"},"n_packages":0,"n_references":4,"next":{"headline":"“This CVE ID is Rejected and will not be used.","id":"CVE-2025-29763"},"packages":[],"prev":{"headline":"MQTT implementation in Sungrow iSolarCloud allowed users to subscribe to all data of all connected inverters","id":"CVE-2025-29756"},"products":["https://oss.growatt.com","https://server.growatt.com"],"published":"2025-07-19","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-07-22","vendors":["Growatt"]},"summary":"An attacker with a valid account can transfer any plant to their own account due to incorrect authorization checks in the Growatt cloud service.","url":"https://insights.sbomify.com/CVE-2025-29757/"}