{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2025-2982 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-2982 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-2982 is a medium-severity path traversal vulnerability in Legrand SMS PowerView, published on 31 Mar 2025. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-2982 and fix it if it is affected.\n\nWhat it is: CVE-2025-2982 is a medium-severity path traversal vulnerability in Legrand SMS PowerView, published on 31 Mar 2025. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2025-2982 in the wild and no public exploit code.\n\nAffected product: Legrand SMS PowerView. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-2982/ (Markdown: https://insights.sbomify.com/CVE-2025-2982/index.md)","id":"CVE-2025-2982","markdown":"https://insights.sbomify.com/CVE-2025-2982/index.md","name":"CVE-2025-2982","record":{"aliases":["GHSA-jpmx-qvrq-8c62"],"analysis":{"component_type":"web_application","fix_type":"no_fix_stated","impacts":["code_execution","data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"PowerView web interface","requires_auth":"low_privilege","summary":"Remote attackers can exploit a file inclusion vulnerability in Legrand SMS PowerView to execute code or read sensitive data.","user_interaction":"not_required","vuln_class":"path_traversal"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulDB","cpe":[],"cvss":{"score":5.3,"severity":"medium","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-73","name":"External Control of File Name or Path"}],"description":"A vulnerability, which was classified as critical, was found in Legrand SMS PowerView 1.x. Affected is an unknown function. The manipulation of the argument redirect leads to file inclusion. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Legrand SMS PowerView file inclusion","id":"CVE-2025-2982","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"path_traversal","year":"2025"},"n_packages":0,"n_references":2,"next":{"headline":"Legrand SMS PowerView os command injection","id":"CVE-2025-2983"},"packages":[],"prev":{"headline":"Legrand SMS PowerView cross site scripting","id":"CVE-2025-2981"},"products":["SMS PowerView"],"published":"2025-03-31","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-03-31","vendors":["Legrand"]},"summary":"Remote attackers can exploit a file inclusion vulnerability in Legrand SMS PowerView to execute code or read sensitive data.","url":"https://insights.sbomify.com/CVE-2025-2982/"}