{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2025-30237 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-30237 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-30237 is a high-severity authentication bypass vulnerability in TP-Link Systems Inc. EX141(BR) V1.0/1.9, published on 10 Aug 2026. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-30237 and fix it if it is affected.\n\nWhat it is: CVE-2025-30237 is a high-severity authentication bypass vulnerability in TP-Link Systems Inc. EX141(BR) V1.0/1.9, published on 10 Aug 2026. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2025-30237 in the wild and no public exploit code.\n\nAffected product: TP-Link Systems Inc. EX141(BR) V1.0/1.9. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-30237/ (Markdown: https://insights.sbomify.com/CVE-2025-30237/index.md)","id":"CVE-2025-30237","markdown":"https://insights.sbomify.com/CVE-2025-30237/index.md","name":"CVE-2025-30237","record":{"aliases":["GHSA-gcr6-hgjr-2h8p"],"analysis":{"component_type":"network_device","fix_type":"patch","impacts":["privilege_escalation","code_execution"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"TP-Link Aginet router","requires_auth":"none","summary":"Unauthenticated attackers can bypass authentication on TP-Link Aginet devices to execute privileged operations and gain full control.","user_interaction":"not_required","vuln_class":"auth_bypass"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"TPLink","cpe":[],"cvss":{"score":8.7,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-862","name":"Missing Authorization"}],"description":"The affected TP-Link Aginet devices contain a flaw in the web management interface where authentication\nchecks are not consistently enforced on certain endpoints. An attacker can send\nspecially crafted requests to bypass authentication and directly invoke\nprivileged functionality without valid credentials. This issue arises from\nimproper enforcement of access control mechanisms on sensitive operations.\n\nSuccessful\nexploitation may allow an unauthenticated attacker to execute privileged\noperations and gain full control of the device.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Authentication Bypass via Broken Access Control in Web Server in Multiple TP-Link Aginet Devices","id":"CVE-2025-30237","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"auth_bypass","year":"2025"},"n_packages":0,"n_references":1,"next":{"headline":"Privilege Escalation via Improper Authorization in User Management in multiple TP-Link Aginet Devices","id":"CVE-2025-30238"},"packages":[],"prev":{"headline":"Auth bypass in SecurAccess","id":"CVE-2025-30236"},"products":["EX141(BR) V1.0/1.9","EX141(EU1) V1.0","EX141(US1) V1.0","EX220(BR) V1.0/1.20/1.28/1.29/1.8","EX220(BR) V2.0","EX220(EU1) V1.0/1.20","EX220(RU) V1.0","EX220(US1) V1.0","EX222(EU1) V1.0","EX222(KR) V1.0","EX222(US1) V1.0","EX511(BR) V2.0/2.8/2.9","EX511(EU1) V2.0","EX511(US1) V2.0","EX520(US1) V1.0","EX520v(EU1)1.0","EX521(US1) V1.0","EX820v(EU1) V1.0","EX920(US2) V1.6/V1.0","HB210 Pro(EU1)1.0","HB210 Pro(US2)1.0/1.6","HB210(EU1) 1.0","HB210(US2) 1.0","HB410( EU1) 1.0","HB610(CA) V2.0","HB610(EU1)","HB610(US2) V2.6/2.0","HB710(EU1) 1.0","HB710(US2) V1.6/1.0","HB810(EU1) V2.0","HB810(US2) V1.0/1.6/2.0/2.6","HC220-G5(BR) V1.30","HC220-G5(EU1) V1.20/1.0","HC220-G5(US1) V1.0/1.6","HX141(EU1) V1.0","HX220(AU) V1.0","HX220(CA) V1.0","HX220(EU1) V1.0","HX220(US1) V1.0/1.6","HX510(AU) V1.0/2.0","HX510(CA) V1.0/2.0","HX510(EU1) V2.0","HX510(US1) V2.0","HX510(US2) 2.6","HX710 Pro(EU1) V1.0","HX710(EU1) V1.0","VX1800v(EU1) V1.0","VX420-G2h(AU) V3.0","VX800v(DE) V1.0","XC220-G3v(EU1) V2.30","XC220-G3v(US1) V2.30","XX230v(BR) V1.0","XX530v(BR)v1.0","XX530v(BR)v2.0","XX530v(EU1)","XX530v(US1)"],"published":"2026-08-10","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2026-10-09","vendors":["TP-Link Systems Inc."]},"summary":"Unauthenticated attackers can bypass authentication on TP-Link Aginet devices to execute privileged operations and gain full control.","url":"https://insights.sbomify.com/CVE-2025-30237/"}