{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2025-30511 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-30511 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-30511 is a high-severity cross-site scripting vulnerability in Growatt Cloud portal, published on 15 Apr 2025. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-30511 and fix it if it is affected.\n\nWhat it is: CVE-2025-30511 is a high-severity cross-site scripting vulnerability in Growatt Cloud portal, published on 15 Apr 2025. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2025-30511 in the wild and no public exploit code.\n\nAffected product: Growatt Cloud portal. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-30511/ (Markdown: https://insights.sbomify.com/CVE-2025-30511/index.md)","id":"CVE-2025-30511","markdown":"https://insights.sbomify.com/CVE-2025-30511/index.md","name":"CVE-2025-30511","record":{"aliases":["GHSA-qc5q-mgx9-379v"],"analysis":{"component_type":"web_application","fix_type":"patch","impacts":["code_execution","account_takeover"],"network_reachable":"yes","non_default_config":false,"product_category":"Growatt Cloud Portal","requires_auth":"low_privilege","summary":"An authenticated attacker can inject malicious scripts via plant names, potentially leading to session hijacking or code execution in the Growatt Cloud Portal.","user_interaction":"not_required","vuln_class":"xss"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"cloud_portal","vendor":"growatt"}],"cvss":{"score":8.7,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-79","name":"Improper Neutralization of Input During Web Page Generation"}],"description":"An authenticated attacker can achieve stored XSS by exploiting improper sanitization of the plant name value while adding or editing a plant.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Growatt Cloud Applications Cross-site Scripting","id":"CVE-2025-30511","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"xss","year":"2025"},"n_packages":0,"n_references":1,"next":{"headline":"Growatt Cloud portal External Control of System or Configuration Setting","id":"CVE-2025-30512"},"packages":[],"prev":{"headline":"Growatt Cloud portal Insufficient Type Distinction","id":"CVE-2025-30510"},"products":["Cloud portal"],"published":"2025-04-15","related":[{"cvss_score":9.3,"headline":"Growatt Cloud portal Cross-site Scripting","id":"CVE-2025-24297","kev_date_added":null,"published":"2025-04-15"},{"cvss_score":9.3,"headline":"Growatt Cloud portal Insufficient Type Distinction","id":"CVE-2025-30510","kev_date_added":null,"published":"2025-04-15"},{"cvss_score":6.9,"headline":"Growatt Cloud portal Authorization Bypass Through User-Controlled Key","id":"CVE-2025-24315","kev_date_added":null,"published":"2025-04-15"},{"cvss_score":6.9,"headline":"Growatt Cloud portal Authorization Bypass Through User-Controlled Key","id":"CVE-2025-24487","kev_date_added":null,"published":"2025-04-15"},{"cvss_score":6.9,"headline":"Growatt Cloud portal Authorization Bypass Through User-Controlled Key","id":"CVE-2025-24850","kev_date_added":null,"published":"2025-04-15"},{"cvss_score":6.9,"headline":"Growatt Cloud portal Authorization Bypass Through User-Controlled Key","id":"CVE-2025-25276","kev_date_added":null,"published":"2025-04-15"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-04-16","vendors":["Growatt"]},"summary":"An authenticated attacker can inject malicious scripts via plant names, potentially leading to session hijacking or code execution in the Growatt Cloud Portal.","url":"https://insights.sbomify.com/CVE-2025-30511/"}