{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2025-3157 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-3157 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-3157 is a medium-severity cross-site scripting vulnerability in Intelbras WRN 150, published on 3 Apr 2025. An attacker needs administrator access to exploit it, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2025-3157 and fix it if it is affected.\n\nWhat it is: CVE-2025-3157 is a medium-severity cross-site scripting vulnerability in Intelbras WRN 150, published on 3 Apr 2025. An attacker needs administrator access to exploit it, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2025-3157 in the wild and no public exploit code.\n\nAffected product: Intelbras WRN 150. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-3157/ (Markdown: https://insights.sbomify.com/CVE-2025-3157/index.md)","id":"CVE-2025-3157","markdown":"https://insights.sbomify.com/CVE-2025-3157/index.md","name":"CVE-2025-3157","record":{"aliases":["GHSA-wgcm-fvrc-r6xc"],"analysis":{"component_type":"network_device","fix_type":"upgrade","impacts":["code_execution","security_bypass"],"network_reachable":"yes","non_default_config":false,"product_category":"Wireless Router","requires_auth":"high_privilege","summary":"Remote attackers can inject malicious scripts via the SSID field in the Intelbras WRN 150 wireless menu, potentially compromising user sessions.","user_interaction":"required","vuln_class":"xss"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulDB","cpe":[],"cvss":{"score":4.8,"severity":"medium","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:P/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-94","name":"Improper Control of Generation of Code"},{"id":"CWE-79","name":"Improper Neutralization of Input During Web Page Generation"}],"description":"A vulnerability was found in Intelbras WRN 150 1.0.15_pt_ITB01. It has been rated as problematic. This issue affects some unknown processing of the component Wireless Menu. The manipulation of the argument SSID leads to cross site scripting. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. It is recommended to upgrade the affected component. The vendor was contacted early about this issue and explains that the latest version is not affected.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Intelbras WRN 150 Wireless Menu cross site scripting","id":"CVE-2025-3157","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"xss","year":"2025"},"n_packages":0,"n_references":3,"next":{"headline":"Open Asset Import Library Assimp LWO File LWOAnimation.cpp UpdateAnimRangeSetup heap-based overflow","id":"CVE-2025-3158"},"packages":[],"prev":{"headline":"This CVE ID has been rejected or withdrawn by its CVE Numbering Authority.","id":"CVE-2025-3156"},"products":["WRN 150"],"published":"2025-04-03","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-04-03","vendors":["Intelbras"]},"summary":"Remote attackers can inject malicious scripts via the SSID field in the Intelbras WRN 150 wireless menu, potentially compromising user sessions.","url":"https://insights.sbomify.com/CVE-2025-3157/"}