{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2025-32831 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-32831 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-32831 is a high-severity SQL injection vulnerability in Siemens Telecontrol Server Basic, published on 16 Apr 2025. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-32831 and fix it if it is affected.\n\nWhat it is: CVE-2025-32831 is a high-severity SQL injection vulnerability in Siemens Telecontrol Server Basic, published on 16 Apr 2025. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2025-32831 in the wild and no public exploit code.\n\nAffected product: Siemens Telecontrol Server Basic. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-32831/ (Markdown: https://insights.sbomify.com/CVE-2025-32831/index.md)","id":"CVE-2025-32831","markdown":"https://insights.sbomify.com/CVE-2025-32831/index.md","name":"CVE-2025-32831","record":{"aliases":["GHSA-2f64-9486-5qm3"],"analysis":{"component_type":"server_software","fix_type":"upgrade","impacts":["code_execution","data_read","data_modify","security_bypass"],"network_reachable":"yes","non_default_config":false,"product_category":"Siemens TeleControl Server","requires_auth":"low_privilege","summary":"An authenticated remote attacker can exploit SQL injection to bypass authorization, read/write database data, and execute code with NetworkService permissions.","user_interaction":"not_required","vuln_class":"sql_injection"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[{"product":"telecontrol_server_basic","vendor":"siemens"}],"cvss":{"score":8.7,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-89","name":"Improper Neutralization of Special Elements used in an SQL Command"}],"description":"A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateProjectUserRights' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"SQL injection in TeleControl Server Basic","id":"CVE-2025-32831","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":"siemens:telecontrol_server_basic","products":["siemens:telecontrol_server_basic"],"type":"sql_injection","year":"2025"},"n_packages":0,"n_references":1,"next":{"headline":"SQL injection in TeleControl Server Basic","id":"CVE-2025-32832"},"packages":[],"prev":{"headline":"SQL injection in TeleControl Server Basic","id":"CVE-2025-32830"},"products":["TeleControl Server Basic"],"published":"2025-04-16","related":[{"cvss_score":10,"headline":"Deserialization in PP TeleControl Server Basic 1000 to 5000 V3.1","id":"CVE-2024-44102","kev_date_added":null,"published":"2024-11-12"},{"cvss_score":9.3,"headline":"Information disclosure in TeleControl Server Basic V3.1","id":"CVE-2025-40765","kev_date_added":null,"published":"2025-10-14"},{"cvss_score":9.3,"headline":"SQL injection in TeleControl Server Basic","id":"CVE-2025-27495","kev_date_added":null,"published":"2025-04-16"},{"cvss_score":9.3,"headline":"SQL injection in TeleControl Server Basic","id":"CVE-2025-27539","kev_date_added":null,"published":"2025-04-16"},{"cvss_score":9.3,"headline":"SQL injection in TeleControl Server Basic","id":"CVE-2025-27540","kev_date_added":null,"published":"2025-04-16"},{"cvss_score":8.8,"headline":"Privilege escalation in TeleControl Server Basic","id":"CVE-2018-4836","kev_date_added":null,"published":"2018-01-25"},{"cvss_score":8.7,"headline":"SQL injection in TeleControl Server Basic","id":"CVE-2025-29905","kev_date_added":null,"published":"2025-04-16"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-04-17","vendors":["Siemens"]},"summary":"An authenticated remote attacker can exploit SQL injection to bypass authorization, read/write database data, and execute code with NetworkService permissions.","url":"https://insights.sbomify.com/CVE-2025-32831/"}