{"answers":{"affected":"","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2025-34042 exists.","fix":"No fix has been published for CVE-2025-34042 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-34042 is a critical command injection vulnerability in Beward N100 IP Camera, published on 26 Jun 2025. An attacker needs administrator access to exploit it, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-34042 and fix it if it is affected.\n\nWhat it is: CVE-2025-34042 is a critical command injection vulnerability in Beward N100 IP Camera, published on 26 Jun 2025. An attacker needs administrator access to exploit it, with no action from the victim.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2025-34042 exists.\n\nAffected product: Beward N100 IP Camera. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-34042/ (Markdown: https://insights.sbomify.com/CVE-2025-34042/index.md)","id":"CVE-2025-34042","markdown":"https://insights.sbomify.com/CVE-2025-34042/index.md","name":"CVE-2025-34042","record":{"aliases":["GHSA-8749-75mj-7339"],"analysis":{"component_type":"iot_embedded","fix_type":"no_fix_stated","impacts":["code_execution","privilege_escalation"],"network_reachable":"yes","non_default_config":false,"product_category":"IP Camera","requires_auth":"high_privilege","summary":"Authenticated attackers can inject system commands via web interface parameters to achieve remote code execution with root privileges on Beward N100 IP Cameras.","user_interaction":"not_required","vuln_class":"command_injection"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulnCheck","cpe":[],"cvss":{"score":9.4,"severity":"critical","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H","version":"4.0"},"cwes":[{"id":"CWE-78","name":"Improper Neutralization of Special Elements used in an OS Command"}],"description":"An authenticated command injection vulnerability exists in the Beward N100 IP Camera firmware version M2.1.6.04C014 via the ServerName and TimeZone parameters in the servetest CGI page. An attacker with access to the web interface can inject arbitrary system commands into these parameters, which are unsafely embedded into backend system calls without proper input sanitization. Successful exploitation results in remote code execution with root privileges. Exploitation evidence was observed by the Shadowserver Foundation on 2024-12-02 UTC.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"weaponised"},"has_fix":null,"headline":"Beward N100 IP Camera Remote Command Execution","id":"CVE-2025-34042","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"command_injection","year":"2025"},"n_packages":0,"n_references":7,"next":{"headline":"Vacron NVR Remote Command Execution","id":"CVE-2025-34043"},"packages":[],"prev":{"headline":"Sangfor Endpoint Detection and Response OS Command Injection","id":"CVE-2025-34041"},"products":["N100 IP Camera"],"published":"2025-06-26","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"poc","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-12-23","vendors":["Beward"]},"summary":"Authenticated attackers can inject system commands via web interface parameters to achieve remote code execution with root privileges on Beward N100 IP Cameras.","url":"https://insights.sbomify.com/CVE-2025-34042/"}