{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2025-34081 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-34081 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-34081 is a medium-severity vulnerability in Contec Co.,Ltd. CONPROSYS HMI System (CHS), published on 1 Jul 2025. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-34081 and fix it if it is affected.\n\nWhat it is: CVE-2025-34081 is a medium-severity vulnerability in Contec Co.,Ltd. CONPROSYS HMI System (CHS), published on 1 Jul 2025. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2025-34081 in the wild and no public exploit code.\n\nAffected product: Contec Co.,Ltd. CONPROSYS HMI System (CHS). No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-34081/ (Markdown: https://insights.sbomify.com/CVE-2025-34081/index.md)","id":"CVE-2025-34081","markdown":"https://insights.sbomify.com/CVE-2025-34081/index.md","name":"CVE-2025-34081","record":{"aliases":["GHSA-7wpp-wf5g-89wp"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"HMI System","requires_auth":"none","summary":"Unauthenticated attackers can access exposed PHP debug information in CONPROSYS HMI System, potentially revealing sensitive configuration data.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulnCheck","cpe":[{"product":"conprosys_hmi_system","vendor":"contec"}],"cvss":{"score":6.9,"severity":"medium","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-215","name":"Insertion of Sensitive Information Into Debugging Code"}],"description":"The Contec Co.,Ltd. CONPROSYS HMI System (CHS) exposes a PHP phpinfo() debug page to unauthenticated users that may contain sensitive data useful for an attacker.This issue affects CONPROSYS HMI System (CHS): before 3.7.7.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"CONPROSYS HMI System (CHS) \u003c 3.7.7 Exposed PHP Debug Info","id":"CVE-2025-34081","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2025"},"n_packages":0,"n_references":2,"next":{"headline":"IGEL OS Secure Terminal and Secure Shadow Remote Code Execution","id":"CVE-2025-34082"},"packages":[],"prev":{"headline":"CONPROSYS HMI System (CHS) \u003c 3.7.7 Reflected Cross-Site Scripting","id":"CVE-2025-34080"},"products":["CONPROSYS HMI System (CHS)"],"published":"2025-07-01","related":[{"cvss_score":9.8,"headline":"Command injection in CONPROSYS HMI System (CHS)","id":"CVE-2022-44456","kev_date_added":null,"published":"2022-12-19"},{"cvss_score":8.8,"headline":"Privilege escalation in CONPROSYS HMI System (CHS)","id":"CVE-2023-28657","kev_date_added":null,"published":"2023-06-01"},{"cvss_score":8.1,"headline":"Information disclosure in CONPROSYS HMI System (CHS)","id":"CVE-2023-28713","kev_date_added":null,"published":"2023-06-01"},{"cvss_score":7.8,"headline":"Missing authorization in CONPROSYS HMI System (CHS)","id":"CVE-2023-28399","kev_date_added":null,"published":"2023-06-01"},{"cvss_score":7.5,"headline":"Hardcoded credentials in CONPROSYS HMI System (CHS)","id":"CVE-2023-22331","kev_date_added":null,"published":"2023-01-20"},{"cvss_score":7.5,"headline":"Missing authorization in CONPROSYS HMI System (CHS)","id":"CVE-2023-22339","kev_date_added":null,"published":"2023-01-20"},{"cvss_score":7.2,"headline":"SQL injection in CONPROSYS HMI System (CHS)","id":"CVE-2023-29154","kev_date_added":null,"published":"2023-06-01"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-11-21","vendors":["Contec Co.,Ltd."]},"summary":"Unauthenticated attackers can access exposed PHP debug information in CONPROSYS HMI System, potentially revealing sensitive configuration data.","url":"https://insights.sbomify.com/CVE-2025-34081/"}