{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2025-34130 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-34130 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-34130 is a high-severity path traversal vulnerability in Merit LILIN DVR Firmware, published on 16 Jul 2025. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-34130 and fix it if it is affected.\n\nWhat it is: CVE-2025-34130 is a high-severity path traversal vulnerability in Merit LILIN DVR Firmware, published on 16 Jul 2025. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2025-34130 in the wild and no public exploit code.\n\nAffected product: Merit LILIN DVR Firmware. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-34130/ (Markdown: https://insights.sbomify.com/CVE-2025-34130/index.md)","id":"CVE-2025-34130","markdown":"https://insights.sbomify.com/CVE-2025-34130/index.md","name":"CVE-2025-34130","record":{"aliases":["GHSA-r252-84qw-9rcg"],"analysis":{"component_type":"iot_embedded","fix_type":"upgrade","impacts":["data_read","security_bypass"],"network_reachable":"yes","non_default_config":false,"product_category":"LILIN DVR firmware","requires_auth":"none","summary":"Unauthenticated attackers can read sensitive configuration files from LILIN DVR devices, potentially enabling further attacks like command injection.","user_interaction":"not_required","vuln_class":"path_traversal"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulnCheck","cpe":[],"cvss":{"score":8.7,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-306","name":"Missing Authentication for Critical Functionality"},{"id":"CWE-200","name":"Exposure of Sensitive Information to an Unauthorized Actor"}],"description":"An unauthenticated arbitrary file read exists in LILIN Digital Video Recorder (DVR) devices prior to firmware version 2.0b60_20200207 via the /z/zbin/net_html.cgi endpoint. This vulnerability allows attackers to read sensitive configuration files, such as /zconf/service.xml, which can then be used to facilitate further attacks including command injection. The vulnerability has been exploited in the wild in conjunction with other issues by botnets like FBot and Moobot.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"LILIN DVR Arbitrary File Read via net_html.cgi","id":"CVE-2025-34130","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"path_traversal","year":"2025"},"n_packages":0,"n_references":3,"next":{"headline":"This CVE ID was rejected because it was reserved but not used for a vulnerability disclosure.","id":"CVE-2025-34131"},"packages":[],"prev":{"headline":"LILIN DVR RCE via Malicious FTP/NTP Configuration","id":"CVE-2025-34129"},"products":["DVR Firmware"],"published":"2025-07-16","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2026-05-15","vendors":["Merit LILIN"]},"summary":"Unauthenticated attackers can read sensitive configuration files from LILIN DVR devices, potentially enabling further attacks like command injection.","url":"https://insights.sbomify.com/CVE-2025-34130/"}