{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2025-3424 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-3424 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-3424 is a high-severity path traversal vulnerability in Philips IntelliSpace Portal, published on 7 Apr 2025. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-3424 and fix it if it is affected.\n\nWhat it is: CVE-2025-3424 is a high-severity path traversal vulnerability in Philips IntelliSpace Portal, published on 7 Apr 2025. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2025-3424 in the wild and no public exploit code.\n\nAffected product: Philips IntelliSpace Portal. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-3424/ (Markdown: https://insights.sbomify.com/CVE-2025-3424/index.md)","id":"CVE-2025-3424","markdown":"https://insights.sbomify.com/CVE-2025-3424/index.md","name":"CVE-2025-3424","record":{"aliases":["GHSA-hg9x-8q33-pg7f"],"analysis":{"component_type":"web_application","fix_type":"upgrade","impacts":["data_read"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Philips IntelliSpace Portal","requires_auth":"none","summary":"An unauthenticated attacker can read internal files via .NET Remoting on port 755 in Philips IntelliSpace Portal.","user_interaction":"not_required","vuln_class":"path_traversal"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"Philips","cpe":[],"cvss":{"score":7.7,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:A/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/S:P/AU:Y/R:U/V:C/RE:M/U:Green","version":"4.0"},"cwes":[{"id":"CWE-22","name":"Improper Limitation of a Pathname to a Restricted Directory"}],"description":"The IntelliSpace portal application utilizes .NET\nRemoting for its functionality. The vulnerability arises from the exploitation\nof port 755 through the \"Object Marshalling\" technique, which allows\nan attacker to read internal files without any authentication. This is possible\nby crafting specific .NET Remoting URLs derived from information enumerated in\nthe client-side configuration files.\n\nThis issue affects IntelliSpace Portal: 12 and prior.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"3.2.1 Arbitrary File Read in insecure .NET Remoting TCP Channel","id":"CVE-2025-3424","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"path_traversal","year":"2025"},"n_packages":0,"n_references":2,"next":{"headline":"Unauthenticated Remote Code Execution via .NET Deserialization","id":"CVE-2025-3425"},"packages":[],"prev":{"headline":"IBM Aspera Faspex 5 cross-site scripting","id":"CVE-2025-3423"},"products":["IntelliSpace Portal"],"published":"2025-04-07","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-04-10","vendors":["Philips"]},"summary":"An unauthenticated attacker can read internal files via .NET Remoting on port 755 in Philips IntelliSpace Portal.","url":"https://insights.sbomify.com/CVE-2025-3424/"}