CVE-2025-3498 Unauthenticated modification of Radiflow iSAP Smart Collector configuration

Critical 9.9 Published Updated

Unauthenticated attackers on the management network can modify system configuration and execute commands via exposed REST APIs.

Exploited in the wild
Not known
Login needed
Not needed
Attackable
Over the internet
Victim action needed
Not needed
Fix
None listed

What is CVE-2025-3498?

CVE-2025-3498 is a critical missing authorization vulnerability in Radiflow iSAP Smart Collector, published on 9 Jul 2025. An attacker can exploit it over the internet without logging in, with no action from the victim.

Official description

An unauthenticated user with management network access can get and modify the Radiflow iSAP Smart Collector (CentOS 7 - VSAP 1.20) configuration. The device has two web servers that expose unauthenticated REST APIs on the management network (TCP ports 8084 and 8086). An attacker can use these APIs to get access to all system settings, modify the configuration and execute some commands (e.g., system reboot).

Weakness: CWE-306

Which versions are affected by CVE-2025-3498?

How do I fix CVE-2025-3498?

No fix has been published for CVE-2025-3498 yet. Limit exposure of the affected software until one is available.

Upgrade, and check permissions on every request on the server, not only in the interface. More about Missing authorization.

Is CVE-2025-3498 being exploited?

There is no known exploitation of CVE-2025-3498 in the wild and no public exploit code.