{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2025-3498 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-3498 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-3498 is a critical missing authorization vulnerability in Radiflow iSAP Smart Collector, published on 9 Jul 2025. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-3498 and fix it if it is affected.\n\nWhat it is: CVE-2025-3498 is a critical missing authorization vulnerability in Radiflow iSAP Smart Collector, published on 9 Jul 2025. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2025-3498 in the wild and no public exploit code.\n\nAffected product: Radiflow iSAP Smart Collector. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-3498/ (Markdown: https://insights.sbomify.com/CVE-2025-3498/index.md)","id":"CVE-2025-3498","markdown":"https://insights.sbomify.com/CVE-2025-3498/index.md","name":"CVE-2025-3498","record":{"aliases":["GHSA-jrmm-gjrx-g69j"],"analysis":{"component_type":"network_device","fix_type":"no_fix_stated","impacts":["data_modify","code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"iSAP Smart Collector","requires_auth":"none","summary":"Unauthenticated attackers on the management network can modify system configuration and execute commands via exposed REST APIs.","user_interaction":"not_required","vuln_class":"missing_authorization"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"ENISA","cpe":[],"cvss":{"score":9.9,"severity":"critical","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:H/A:L","version":"3.1"},"cwes":[{"id":"CWE-306","name":"Missing Authentication for Critical Functionality"}],"description":"An unauthenticated user with management network access can get and \nmodify the Radiflow iSAP Smart Collector (CentOS 7 - VSAP 1.20) \nconfiguration. The device has two web servers that expose unauthenticated REST APIs on the management network (TCP\nports 8084 and 8086). An attacker can use these APIs to get access to all system settings, modify the configuration\nand execute some commands (e.g., system reboot).","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Unauthenticated modification of Radiflow iSAP Smart Collector configuration","id":"CVE-2025-3498","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"missing_authorization","year":"2025"},"n_packages":0,"n_references":1,"next":{"headline":"Unauthenticated execution of arbitrary commands in Radiflow iSAP Smart Collector","id":"CVE-2025-3499"},"packages":[],"prev":{"headline":"Radiflow iSAP Smart Collector Linux distribution unmaintained","id":"CVE-2025-3497"},"products":["iSAP Smart Collector"],"published":"2025-07-09","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-07-09","vendors":["Radiflow"]},"summary":"Unauthenticated attackers on the management network can modify system configuration and execute commands via exposed REST APIs.","url":"https://insights.sbomify.com/CVE-2025-3498/"}