{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2025-36511 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-36511 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-36511 is a medium-severity vulnerability in Intel(R) Memory and Storage Tool, published on 10 Feb 2026. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2025-36511 and fix it if it is affected.\n\nWhat it is: CVE-2025-36511 is a medium-severity vulnerability in Intel(R) Memory and Storage Tool, published on 10 Feb 2026. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2025-36511 in the wild and no public exploit code.\n\nAffected product: Intel(R) Memory and Storage Tool. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-36511/ (Markdown: https://insights.sbomify.com/CVE-2025-36511/index.md)","id":"CVE-2025-36511","markdown":"https://insights.sbomify.com/CVE-2025-36511/index.md","name":"CVE-2025-36511","record":{"aliases":["GHSA-3hfp-x6f5-mjw5"],"analysis":{"component_type":"desktop_application","fix_type":"upgrade","impacts":["privilege_escalation"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Intel Memory Storage Tool","requires_auth":"low_privilege","summary":"An authenticated local attacker can escalate privileges due to incorrect default permissions in the Intel Memory and Storage Tool.","user_interaction":"required","vuln_class":"privilege_escalation"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"intel","cpe":[],"cvss":{"score":5.4,"severity":"medium","source":"cna","vector":"CVSS:4.0/AV:L/AC:H/AT:P/PR:L/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-276","name":"Incorrect Default Permissions"}],"description":"Incorrect default permissions for some Intel(R) Memory and Storage Tool before version 2.5.2 within Ring 3: User Applications may allow an escalation of privilege. System software adversary with an authenticated user combined with a high complexity attack may enable escalation of privilege. This result may potentially occur via local access when attack requirements are present without special internal knowledge and requires active user interaction. The potential vulnerability may impact the confidentiality (high), integrity (high) and availability (high) of the vulnerable system, resulting in subsequent system confidentiality (none), integrity (none) and availability (none) impacts.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Privilege escalation in Intel(R) Memory and Storage Tool","id":"CVE-2025-36511","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"privilege_escalation","year":"2025"},"n_packages":0,"n_references":1,"next":{"headline":"Denial of service in Comdb2","id":"CVE-2025-36512"},"packages":[],"prev":{"headline":"Denial of service in Display Virtualization for Windows OS driver software","id":"CVE-2025-36510"},"products":["Intel(R) Memory and Storage Tool"],"published":"2026-02-10","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2026-02-26","vendors":["n/a"]},"summary":"An authenticated local attacker can escalate privileges due to incorrect default permissions in the Intel Memory and Storage Tool.","url":"https://insights.sbomify.com/CVE-2025-36511/"}