{"answers":{"affected":"It affects 1 product.","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2025-3693 exists.","fix":"No fix has been published for CVE-2025-3693 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-3693 is a high-severity memory corruption vulnerability in Tenda W12, published on 16 Apr 2025. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-3693 and fix it if it is affected.\n\nWhat it is: CVE-2025-3693 is a high-severity memory corruption vulnerability in Tenda W12, published on 16 Apr 2025. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2025-3693 exists.\n\nAffected product: Tenda W12. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-3693/ (Markdown: https://insights.sbomify.com/CVE-2025-3693/index.md)","id":"CVE-2025-3693","markdown":"https://insights.sbomify.com/CVE-2025-3693/index.md","name":"CVE-2025-3693","record":{"aliases":["GHSA-mxvx-cwcc-38xf"],"analysis":{"component_type":"network_device","fix_type":"no_fix_stated","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"Tenda W12 router","requires_auth":"low_privilege","summary":"A remote attacker can trigger a stack-based buffer overflow in the Tenda W12 router's httpd service to execute arbitrary code.","user_interaction":"not_required","vuln_class":"memory_corruption"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulDB","cpe":[{"product":"w12_firmware","vendor":"tenda"}],"cvss":{"score":8.7,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-121","name":"Stack-based Buffer Overflow"},{"id":"CWE-119","name":"Improper Restriction of Operations within the Bounds of a Memory Buffer"}],"description":"A vulnerability was found in Tenda W12 3.0.0.5. It has been rated as critical. Affected by this issue is the function cgiWifiRadioSet of the file /bin/httpd. The manipulation leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"weaponised"},"has_fix":null,"headline":"Tenda W12 httpd cgiWifiRadioSet stack-based overflow","id":"CVE-2025-3693","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"memory_corruption","year":"2025"},"n_packages":0,"n_references":5,"next":{"headline":"SourceCodester Web-based Pharmacy Product Management System Login sql injection","id":"CVE-2025-3694"},"packages":[],"prev":{"headline":"SourceCodester Online Eyewear Shop Master.php cross site scripting","id":"CVE-2025-3692"},"products":["W12"],"published":"2025-04-16","related":[{"cvss_score":8.7,"headline":"Tenda W12 HTTP Request modules wifiMacFilterSet stack-based overflow","id":"CVE-2025-11549","kev_date_added":null,"published":"2025-10-09"},{"cvss_score":7.1,"headline":"Tenda W12 HTTP Request modules wifiScheduledSet null pointer dereference","id":"CVE-2025-11550","kev_date_added":null,"published":"2025-10-09"},{"cvss_score":1.8,"headline":"Tenda W12 Administrative shadow hard-coded credentials","id":"CVE-2025-9778","kev_date_added":null,"published":"2025-09-01"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"poc","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-04-16","vendors":["Tenda"]},"summary":"A remote attacker can trigger a stack-based buffer overflow in the Tenda W12 router's httpd service to execute arbitrary code.","url":"https://insights.sbomify.com/CVE-2025-3693/"}