{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2025-37144 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-37144 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-37144 is a medium-severity path traversal vulnerability in Arubanetworks Arubaos, published on 14 Oct 2025. An attacker needs administrator access to exploit it, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-37144 and fix it if it is affected.\n\nWhat it is: CVE-2025-37144 is a medium-severity path traversal vulnerability in Arubanetworks Arubaos, published on 14 Oct 2025. An attacker needs administrator access to exploit it, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2025-37144 in the wild and no public exploit code.\n\nAffected product: Arubanetworks Arubaos. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-37144/ (Markdown: https://insights.sbomify.com/CVE-2025-37144/index.md)","id":"CVE-2025-37144","markdown":"https://insights.sbomify.com/CVE-2025-37144/index.md","name":"CVE-2025-37144","record":{"aliases":["GHSA-q5jp-gqxh-2wv5"],"analysis":{"component_type":"network_device","fix_type":"patch","impacts":["data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"ArubaOS network controller","requires_auth":"high_privilege","summary":"Authenticated attackers can download arbitrary files from ArubaOS network devices via a path traversal vulnerability in the management interface.","user_interaction":"not_required","vuln_class":"path_traversal"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"hpe","cpe":[{"product":"arubaos","vendor":"arubanetworks"}],"cvss":{"score":4.9,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N","version":"3.1"},"cwes":[{"id":"CWE-22","name":"Improper Limitation of a Pathname to a Restricted Directory"}],"description":"Arbitrary file download vulnerabilities exist in a low-level interface library in AOS-10 GW and AOS-8 Controller/Mobility Conductor operating systems. Successful exploitation could allow an authenticated malicious actor to download arbitrary files through carefully constructed exploits.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Path traversal in ArubaOS (AOS)","id":"CVE-2025-37144","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":"arubanetworks:arubaos","products":["arubanetworks:arubaos"],"type":"path_traversal","year":"2025"},"n_packages":0,"n_references":1,"next":{"headline":"Path traversal in ArubaOS (AOS)","id":"CVE-2025-37145"},"packages":[],"prev":{"headline":"Path traversal in ArubaOS (AOS)","id":"CVE-2025-37143"},"products":["ArubaOS (AOS)"],"published":"2025-10-14","related":[{"cvss_score":9.8,"headline":"Memory corruption in Hpe Aruba Networking InstantOS and Aruba Access Points running ArubaOS 10","id":"CVE-2024-42393","kev_date_added":null,"published":"2024-08-06"},{"cvss_score":9.8,"headline":"Memory corruption in HPE Aruba Networking InstantOS and Aruba Access Points running ArubaOS 10","id":"CVE-2024-42394","kev_date_added":null,"published":"2024-08-06"},{"cvss_score":9.8,"headline":"Memory corruption in HPE Aruba Networking InstantOS and Aruba Access Points running ArubaOS 10","id":"CVE-2024-42395","kev_date_added":null,"published":"2024-08-06"},{"cvss_score":9.8,"headline":"Unauthenticated Buffer Overflow Vulnerabilities in CLI Service Accessed by the PAPI Protocol","id":"CVE-2024-31466","kev_date_added":null,"published":"2024-05-14"},{"cvss_score":9.8,"headline":"Unauthenticated Buffer Overflow Vulnerabilities in CLI Service Accessed by the PAPI Protocol","id":"CVE-2024-31467","kev_date_added":null,"published":"2024-05-14"},{"cvss_score":9.8,"headline":"Memory corruption in AOS-8 Instant and AOS-10 AP","id":"CVE-2024-31468","kev_date_added":null,"published":"2024-05-14"},{"cvss_score":9.8,"headline":"Memory corruption in AOS-8 Instant and AOS-10 AP","id":"CVE-2024-31469","kev_date_added":null,"published":"2024-05-14"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-10-15","vendors":["Hewlett Packard Enterprise (HPE)"]},"summary":"Authenticated attackers can download arbitrary files from ArubaOS network devices via a path traversal vulnerability in the management interface.","url":"https://insights.sbomify.com/CVE-2025-37144/"}