{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2025-40582 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-40582 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-40582 is a high-severity command injection vulnerability in Siemens SCALANCE LPE9403, published on 13 May 2025. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-40582 and fix it if it is affected.\n\nWhat it is: CVE-2025-40582 is a high-severity command injection vulnerability in Siemens SCALANCE LPE9403, published on 13 May 2025. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2025-40582 in the wild and no public exploit code.\n\nAffected product: Siemens SCALANCE LPE9403. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-40582/ (Markdown: https://insights.sbomify.com/CVE-2025-40582/index.md)","id":"CVE-2025-40582","markdown":"https://insights.sbomify.com/CVE-2025-40582/index.md","name":"CVE-2025-40582","record":{"aliases":["GHSA-hww9-6wv5-mrp9"],"analysis":{"component_type":"network_device","fix_type":"upgrade","impacts":["code_execution","privilege_escalation"],"network_reachable":"adjacent_or_local","non_default_config":true,"product_category":"SCALANCE LPE9403","requires_auth":"low_privilege","summary":"A local attacker can execute root commands on SCALANCE LPE9403 devices if the SINEMA Remote Connect Edge Client is installed.","user_interaction":"not_required","vuln_class":"command_injection"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[{"product":"scalance_lpe9403_firmware","vendor":"siemens"}],"cvss":{"score":8.5,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-78","name":"Improper Neutralization of Special Elements used in an OS Command"}],"description":"A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions \u003c V2.1 HF0 with SINEMA Remote Connect Edge Client installed). Affected devices do not properly sanitize configuration parameters.\r\nThis could allow a non-privileged local attacker to execute root commands on the device.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Command injection in SCALANCE LPE9403","id":"CVE-2025-40582","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"command_injection","year":"2025"},"n_packages":0,"n_references":1,"next":{"headline":"Information disclosure in SCALANCE LPE9403","id":"CVE-2025-40583"},"packages":[],"prev":{"headline":"Auth bypass in SCALANCE LPE9403","id":"CVE-2025-40581"},"products":["SCALANCE LPE9403"],"published":"2025-05-13","related":[{"cvss_score":9.9,"headline":"Command injection in SCALANCE LPE9403","id":"CVE-2023-27407","kev_date_added":null,"published":"2023-05-09"},{"cvss_score":8.7,"headline":"Privilege escalation in SCALANCE LPE9403","id":"CVE-2025-27396","kev_date_added":null,"published":"2025-03-11"},{"cvss_score":8.6,"headline":"Command injection in SCALANCE LPE9403","id":"CVE-2025-27392","kev_date_added":null,"published":"2025-03-11"},{"cvss_score":8.6,"headline":"Command injection in SCALANCE LPE9403","id":"CVE-2025-27393","kev_date_added":null,"published":"2025-03-11"},{"cvss_score":8.6,"headline":"Command injection in SCALANCE LPE9403","id":"CVE-2025-27394","kev_date_added":null,"published":"2025-03-11"},{"cvss_score":8.6,"headline":"Path traversal in SCALANCE LPE9403","id":"CVE-2025-27395","kev_date_added":null,"published":"2025-03-11"},{"cvss_score":8.5,"headline":"Missing authorization in SCALANCE LPE9403","id":"CVE-2025-40574","kev_date_added":null,"published":"2025-05-13"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2026-09-08","vendors":["Siemens"]},"summary":"A local attacker can execute root commands on SCALANCE LPE9403 devices if the SINEMA Remote Connect Edge Client is installed.","url":"https://insights.sbomify.com/CVE-2025-40582/"}