{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2025-40585 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-40585 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-40585 is a critical vulnerability in Siemens Energy Services, published on 10 Jun 2025. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-40585 and fix it if it is affected.\n\nWhat it is: CVE-2025-40585 is a critical vulnerability in Siemens Energy Services, published on 10 Jun 2025. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2025-40585 in the wild and no public exploit code.\n\nAffected product: Siemens Energy Services. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-40585/ (Markdown: https://insights.sbomify.com/CVE-2025-40585/index.md)","id":"CVE-2025-40585","markdown":"https://insights.sbomify.com/CVE-2025-40585/index.md","name":"CVE-2025-40585","record":{"aliases":["GHSA-8rxv-vgf4-465c"],"analysis":{"component_type":"ics_ot","fix_type":"no_fix_stated","impacts":["privilege_escalation","data_modify"],"network_reachable":"yes","non_default_config":false,"product_category":"Siemens Energy Services","requires_auth":"none","summary":"Attackers can use default credentials to gain control of the G5DFR component and tamper with device outputs in Siemens Energy Services.","user_interaction":"not_required","vuln_class":"hardcoded_credentials"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[],"cvss":{"score":9.5,"severity":"critical","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:L/SI:H/SA:L","version":"4.0"},"cwes":[{"id":"CWE-276","name":"Incorrect Default Permissions"}],"description":"A vulnerability has been identified in Energy Services (All versions with G5DFR). Affected solutions using G5DFR contain default credentials. This could allow an attacker to gain control of G5DFR component and tamper with outputs from the device.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Hardcoded credentials in Energy Services","id":"CVE-2025-40585","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"hardcoded_credentials","year":"2025"},"n_packages":0,"n_references":1,"next":{"headline":"Cross-site scripting in Polarion V2404","id":"CVE-2025-40587"},"packages":[],"prev":{"headline":"XML external entity in SIMOTION SCOUT TIA V5.4","id":"CVE-2025-40584"},"products":["Energy Services"],"published":"2025-06-10","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-06-10","vendors":["Siemens"]},"summary":"Attackers can use default credentials to gain control of the G5DFR component and tamper with device outputs in Siemens Energy Services.","url":"https://insights.sbomify.com/CVE-2025-40585/"}