{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2025-40753 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-40753 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-40753 is a medium-severity vulnerability in Siemens POWER METER SICAM Q100, published on 12 Aug 2025. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-40753 and fix it if it is affected.\n\nWhat it is: CVE-2025-40753 is a medium-severity vulnerability in Siemens POWER METER SICAM Q100, published on 12 Aug 2025. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2025-40753 in the wild and no public exploit code.\n\nAffected product: Siemens POWER METER SICAM Q100. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-40753/ (Markdown: https://insights.sbomify.com/CVE-2025-40753/index.md)","id":"CVE-2025-40753","markdown":"https://insights.sbomify.com/CVE-2025-40753/index.md","name":"CVE-2025-40753","record":{"aliases":["GHSA-f62w-hhpc-j73f"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["data_read"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Siemens power meter","requires_auth":"low_privilege","summary":"An authenticated local attacker can extract the SMTP password from the configuration file of Siemens SICAM power meters.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[],"cvss":{"score":6.8,"severity":"medium","source":"cna","vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-312","name":"Cleartext Storage of Sensitive Information"}],"description":"A vulnerability has been identified in POWER METER SICAM Q100 (7KG9501-0AA01-0AA1) (All versions \u003e= V2.60 \u003c V2.62), POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) (All versions \u003e= V2.60 \u003c V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-0AA1) (All versions \u003e= V2.60 \u003c V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-2AA1) (All versions \u003e= V2.60 \u003c V2.62), POWER METER SICAM Q200 family (All versions \u003e= V2.70 \u003c V2.80). Affected devices export the password for the SMTP account as plain text in the Configuration File. This could allow an authenticated local attacker to extract it and use the configured SMTP service for arbitrary purposes.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Information disclosure in POWER METER SICAM Q100","id":"CVE-2025-40753","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2025"},"n_packages":0,"n_references":1,"next":{"headline":"SQL injection in SINEC NMS","id":"CVE-2025-40755"},"packages":[],"prev":{"headline":"Information disclosure in POWER METER SICAM Q100","id":"CVE-2025-40752"},"products":["POWER METER SICAM Q100","POWER METER SICAM Q200 family"],"published":"2025-08-12","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-08-13","vendors":["Siemens"]},"summary":"An authenticated local attacker can extract the SMTP password from the configuration file of Siemens SICAM power meters.","url":"https://insights.sbomify.com/CVE-2025-40753/"}