{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2025-40802 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-40802 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-40802 is a low-severity denial of service vulnerability in Siemens RUGGEDCOM RST2428P, published on 9 Sep 2025. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-40802 and fix it if it is affected.\n\nWhat it is: CVE-2025-40802 is a low-severity denial of service vulnerability in Siemens RUGGEDCOM RST2428P, published on 9 Sep 2025. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2025-40802 in the wild and no public exploit code.\n\nAffected product: Siemens RUGGEDCOM RST2428P. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-40802/ (Markdown: https://insights.sbomify.com/CVE-2025-40802/index.md)","id":"CVE-2025-40802","markdown":"https://insights.sbomify.com/CVE-2025-40802/index.md","name":"CVE-2025-40802","record":{"aliases":["GHSA-49wx-m47g-hrrr"],"analysis":{"component_type":"network_device","fix_type":"no_fix_stated","impacts":["denial_of_service"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Industrial network switch","requires_auth":"none","summary":"An attacker can cause a temporary denial of service on Siemens RUGGEDCOM switches by flooding them with high volumes of query requests.","user_interaction":"not_required","vuln_class":"denial_of_service"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[{"product":"ruggedcom_rst2428p_firmware","vendor":"siemens"}],"cvss":{"score":2.3,"severity":"low","source":"cna","vector":"CVSS:4.0/AV:A/AC:H/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-400","name":"Uncontrolled Resource Consumption"}],"description":"A vulnerability has been identified in RUGGEDCOM RST2428P (6GK6242-6PA00) (All versions). The affected device may be susceptible to resource exhaustion when subjected to high volumes of query requests.\r\nThis could allow an attacker to cause a temporary denial of service, with the system recovering once the activity stops.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Denial of service in RUGGEDCOM RST2428P","id":"CVE-2025-40802","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"denial_of_service","year":"2025"},"n_packages":0,"n_references":1,"next":{"headline":"Information disclosure in RUGGEDCOM RST2428P","id":"CVE-2025-40803"},"packages":[],"prev":{"headline":"Weak cryptography in COMOS V10.6","id":"CVE-2025-40801"},"products":["RUGGEDCOM RST2428P"],"published":"2025-09-09","related":[{"cvss_score":2.3,"headline":"Information disclosure in RUGGEDCOM RST2428P","id":"CVE-2025-40803","kev_date_added":null,"published":"2025-09-09"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-09-09","vendors":["Siemens"]},"summary":"An attacker can cause a temporary denial of service on Siemens RUGGEDCOM switches by flooding them with high volumes of query requests.","url":"https://insights.sbomify.com/CVE-2025-40802/"}