{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2025-40817 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-40817 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-40817 is a high-severity missing authorization vulnerability in Siemens LOGO! 12/24RCE, published on 11 Nov 2025. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-40817 and fix it if it is affected.\n\nWhat it is: CVE-2025-40817 is a high-severity missing authorization vulnerability in Siemens LOGO! 12/24RCE, published on 11 Nov 2025. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2025-40817 in the wild and no public exploit code.\n\nAffected product: Siemens LOGO! 12/24RCE. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-40817/ (Markdown: https://insights.sbomify.com/CVE-2025-40817/index.md)","id":"CVE-2025-40817","markdown":"https://insights.sbomify.com/CVE-2025-40817/index.md","name":"CVE-2025-40817","record":{"aliases":["GHSA-rx6m-vh7q-5563"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["data_modify"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Siemens LOGO! PLC","requires_auth":"none","summary":"An unauthenticated remote attacker can modify the device time, causing the PLC to behave differently due to missing validation checks.","user_interaction":"not_required","vuln_class":"missing_authorization"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[],"cvss":{"score":7.1,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-306","name":"Missing Authentication for Critical Functionality"}],"description":"A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions \u003c V1.84.05), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions \u003c V1.84.05), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions \u003c V1.84.05), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions \u003c V1.84.05), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions \u003c V1.84.05), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions \u003c V1.84.05), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions \u003c V1.84.05), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions \u003c V1.84.05), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions \u003c V1.84.05), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions \u003c V1.84.05), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions \u003c V1.84.05), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions \u003c V1.84.05), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions \u003c V1.84.05), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions \u003c V1.84.05), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions \u003c V1.84.05), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions \u003c V1.84.05). Affected devices do not conduct certain validations when interacting with them. This could allow an unauthenticated remote attacker to change time of the device, which means the device could behave differently.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Missing authorization in LOGO! 12/24RCE","id":"CVE-2025-40817","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"missing_authorization","year":"2025"},"n_packages":0,"n_references":1,"next":{"headline":"Information disclosure in SINEMA Remote Connect Server","id":"CVE-2025-40818"},"packages":[],"prev":{"headline":"Missing authorization in LOGO! 12/24RCE","id":"CVE-2025-40816"},"products":["LOGO! 12/24RCE","LOGO! 12/24RCEo","LOGO! 230RCE","LOGO! 230RCEo","LOGO! 24CE","LOGO! 24CEo","LOGO! 24RCE","LOGO! 24RCEo","SIPLUS LOGO! 12/24RCE","SIPLUS LOGO! 12/24RCEo","SIPLUS LOGO! 230RCE","SIPLUS LOGO! 230RCEo","SIPLUS LOGO! 24CE","SIPLUS LOGO! 24CEo","SIPLUS LOGO! 24RCE","SIPLUS LOGO! 24RCEo"],"published":"2025-11-11","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2026-10-13","vendors":["Siemens"]},"summary":"An unauthenticated remote attacker can modify the device time, causing the PLC to behave differently due to missing validation checks.","url":"https://insights.sbomify.com/CVE-2025-40817/"}