{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2025-41690 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-41690 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-41690 is a high-severity vulnerability in Endress+Hauser Promag 10 with HART, published on 2 Sep 2025. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2025-41690 and fix it if it is affected.\n\nWhat it is: CVE-2025-41690 is a high-severity vulnerability in Endress+Hauser Promag 10 with HART, published on 2 Sep 2025. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2025-41690 in the wild and no public exploit code.\n\nAffected product: Endress+Hauser Promag 10 with HART. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-41690/ (Markdown: https://insights.sbomify.com/CVE-2025-41690/index.md)","id":"CVE-2025-41690","markdown":"https://insights.sbomify.com/CVE-2025-41690/index.md","name":"CVE-2025-41690","record":{"aliases":["GHSA-rjm8-q5m3-8v9h"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["privilege_escalation","data_modify"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Industrial flow meters","requires_auth":"low_privilege","summary":"A low-privileged attacker can view maintenance credentials in event logs via Bluetooth, enabling unauthorized access and modification of device parameters.","user_interaction":"required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"CERTVDE","cpe":[],"cvss":{"score":7.4,"severity":"high","source":"cna","vector":"CVSS:3.1/AV:A/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-532","name":"Insertion of Sensitive Information into Log File"}],"description":"A low-privileged attacker in bluetooth range may be able to access the password of a higher-privilege user (Maintenance) by viewing the device’s event log. This vulnerability could allow the Operator to authenticate as the Maintenance user, thereby gaining unauthorized access to sensitive configuration settings and the ability to modify device parameters.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Endress+Hauser: Proline 10 Maintenance credentials may be exposed under certain conditions","id":"CVE-2025-41690","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2025"},"n_packages":0,"n_references":1,"next":{"headline":"CODESYS Control DoS via Unauthenticated NULL Pointer Dereference","id":"CVE-2025-41691"},"packages":[],"prev":{"headline":"Wiesemann \u0026 Theis: Motherbox 3 allows unauthenticated read-only DB access","id":"CVE-2025-41689"},"products":["Promag 10 with HART","Promag 10 with IO-Link","Promag 10 with Modbus","Promass 10 with HART","Promass 10 with IO-Link","Promass 10 with Modbus"],"published":"2025-09-02","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-09-02","vendors":["Endress+Hauser"]},"summary":"A low-privileged attacker can view maintenance credentials in event logs via Bluetooth, enabling unauthorized access and modification of device parameters.","url":"https://insights.sbomify.com/CVE-2025-41690/"}