{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2025-41708 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-41708 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-41708 is a high-severity vulnerability in Bender CC612, published on 8 Sep 2025. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-41708 and fix it if it is affected.\n\nWhat it is: CVE-2025-41708 is a high-severity vulnerability in Bender CC612, published on 8 Sep 2025. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2025-41708 in the wild and no public exploit code.\n\nAffected product: Bender CC612. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-41708/ (Markdown: https://insights.sbomify.com/CVE-2025-41708/index.md)","id":"CVE-2025-41708","markdown":"https://insights.sbomify.com/CVE-2025-41708/index.md","name":"CVE-2025-41708","record":{"aliases":["GHSA-mhvx-p45m-25xf"],"analysis":{"component_type":"iot_embedded","fix_type":"configuration_change","impacts":["data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"Industrial controller","requires_auth":"none","summary":"An attacker on the same network can intercept sensitive data transmitted over HTTP due to insecure default web interface settings.","user_interaction":"not_required","vuln_class":"misconfiguration"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"CERTVDE","cpe":[],"cvss":{"score":7.4,"severity":"high","source":"cna","vector":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N","version":"3.1"},"cwes":[{"id":"CWE-319","name":"Cleartext Transmission of Sensitive Information"}],"description":"Due to an unsecure default configuration HTTP is used instead of HTTPS for the web interface. An unauthenticated attacker on the same network could exploit this to learn sensitive data during transmission.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Cleartext Transmission of Sensitive Data via Insecure HTTP Web Interface","id":"CVE-2025-41708","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"misconfiguration","year":"2025"},"n_packages":0,"n_references":1,"next":{"headline":"Command injection in power analyzer via Modbus-TCP and Modbus-RTU","id":"CVE-2025-41709"},"packages":[],"prev":{"headline":"Phoenix Contact: WebSocket Handler Denial of Service","id":"CVE-2025-41707"},"products":["CC612","CC613","ICC13xx","ICC15xx","ICC16xx"],"published":"2025-09-08","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-09-08","vendors":["Bender"]},"summary":"An attacker on the same network can intercept sensitive data transmitted over HTTP due to insecure default web interface settings.","url":"https://insights.sbomify.com/CVE-2025-41708/"}