{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2025-41712 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-41712 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-41712 is a medium-severity missing authorization vulnerability in Janitza ENERGY METER 750-230 (2540910000), published on 10 Mar 2026. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2025-41712 and fix it if it is affected.\n\nWhat it is: CVE-2025-41712 is a medium-severity missing authorization vulnerability in Janitza ENERGY METER 750-230 (2540910000), published on 10 Mar 2026. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2025-41712 in the wild and no public exploit code.\n\nAffected product: Janitza ENERGY METER 750-230 (2540910000). No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-41712/ (Markdown: https://insights.sbomify.com/CVE-2025-41712/index.md)","id":"CVE-2025-41712","markdown":"https://insights.sbomify.com/CVE-2025-41712/index.md","name":"CVE-2025-41712","record":{"aliases":["GHSA-j6m2-p2p5-pmqj"],"analysis":{"component_type":"iot_embedded","fix_type":"patch","impacts":["data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"Power analyzer","requires_auth":"none","summary":"An unauthenticated attacker can access sensitive information on Janitza and Weidmueller power analyzers by tricking a user into uploading a manipulated HTML file due to incorrect web server permissions.","user_interaction":"required","vuln_class":"missing_authorization"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"CERTVDE","cpe":[],"cvss":{"score":6.5,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N","version":"3.1"},"cwes":[{"id":"CWE-732","name":"Incorrect Permission Assignment for Critical Resource"}],"description":"An unauthenticated remote attacker who tricks a user to upload a manipulated HTML file can get access to sensitive information on the device. This is a result of incorrect permission assignment for the web server.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Incorrect Permission Assignment on power analyzer","id":"CVE-2025-41712","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"missing_authorization","year":"2025"},"n_packages":0,"n_references":4,"next":{"headline":"WAGO: Vulnerability in hardware switch circuit","id":"CVE-2025-41713"},"packages":[],"prev":{"headline":"Use of a Broken or Risky Cryptographic Algorithm for firmware images of power analyzer","id":"CVE-2025-41711"},"products":["ENERGY METER 750-230 (2540910000)","ENERGY METER 750-24 (2540900000)","UMG 96RM-E 230V(5222062)","UMG 96RM-E 24V(5222063)"],"published":"2026-03-10","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2026-03-10","vendors":["Janitza","Weidmueller"]},"summary":"An unauthenticated attacker can access sensitive information on Janitza and Weidmueller power analyzers by tricking a user into uploading a manipulated HTML file due to incorrect web server permissions.","url":"https://insights.sbomify.com/CVE-2025-41712/"}