{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2025-41713 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-41713 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-41713 is a medium-severity vulnerability in WAGO CC100 0751-9301, published on 15 Sep 2025. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-41713 and fix it if it is affected.\n\nWhat it is: CVE-2025-41713 is a medium-severity vulnerability in WAGO CC100 0751-9301, published on 15 Sep 2025. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2025-41713 in the wild and no public exploit code.\n\nAffected product: WAGO CC100 0751-9301. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-41713/ (Markdown: https://insights.sbomify.com/CVE-2025-41713/index.md)","id":"CVE-2025-41713","markdown":"https://insights.sbomify.com/CVE-2025-41713/index.md","name":"CVE-2025-41713","record":{"aliases":["GHSA-4x6r-qc3x-j39x"],"analysis":{"component_type":"network_device","fix_type":"patch","impacts":["security_bypass"],"network_reachable":"yes","non_default_config":false,"product_category":"Industrial network switch","requires_auth":"none","summary":"An unauthenticated remote attacker can bypass network segmentation during device boot due to undefined switch state, requiring firmware updates for WAGO CC100 switches.","user_interaction":"not_required","vuln_class":"security_feature_bypass"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"CERTVDE","cpe":[],"cvss":{"score":6.5,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:L","version":"3.1"},"cwes":[{"id":"CWE-1188","name":"Initialization of a Resource with an Insecure Default"}],"description":"During a short time frame while the device is booting an unauthenticated remote attacker can send traffic to unauthorized networks due to the switch operating in an undefined state until a CPU-induced reset allows proper configuration.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"WAGO: Vulnerability in hardware switch circuit","id":"CVE-2025-41713","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"security_feature_bypass","year":"2025"},"n_packages":0,"n_references":2,"next":{"headline":"Path Traversal via 'Upload-Key' in SmartEMS Upload Handling","id":"CVE-2025-41714"},"packages":[],"prev":{"headline":"Incorrect Permission Assignment on power analyzer","id":"CVE-2025-41712"},"products":["CC100 0751-9301","CC100 0751-9301 HW rev. \u0026lt;082100","CC100 0751-9301/K000-0005","CC100 0751-9301/K000-0005 HW rev. \u0026lt;082100","CC100 0751-9401","CC100 0751-9401 HW rev. \u0026lt;052500","CC100 0751-9402","CC100 0751-9402 HW rev. \u0026lt;032800","CC100 0751-9402/0000-0001","CC100 0751-9402/0000-0001 HW rev. \u0026lt;052800","CC100 0751-9403","CC100 0751-9403 HW rev. \u0026lt;022800","Edge Controller 0752-8303/8000-0002","Edge Controller 0752-8303/8000-0002 HW rev. 32500","TP600 0762-4101","TP600 0762-4101 HW rev. \u0026lt;072500","TP600 0762-4102","TP600 0762-4102 HW rev. \u0026lt;072500","TP600 0762-4104","TP600 0762-4104 HW rev. \u0026lt;062500","TP600 0762-4201/8000-0001","TP600 0762-4201/8000-0001 HW rev. \u0026lt;072500","TP600 0762-4201/8000-0002","TP600 0762-4201/8000-0002 HW rev. \u0026lt;072500","TP600 0762-4301/8000-0002","TP600 0762-4301/8000-0002 HW rev. \u0026lt;072500","TP600 0762-4302/8000-0002","TP600 0762-4302/8000-0002 HW rev. \u0026lt;072500","TP600 0762-4303/8000-0002","TP600 0762-4303/8000-0002 HW rev. \u0026lt;062500","TP600 0762-4304/8000-0002","TP600 0762-4304/8000-0002 HW rev. \u0026lt;062500","TP600 0762-4305/8000-0002","TP600 0762-4305/8000-0002 HW rev. \u0026lt;052500","TP600 0762-4306/8000-0001","TP600 0762-4306/8000-0001 HW rev. \u0026lt;042500","TP600 0762-4306/8000-0002","TP600 0762-4306/8000-0002 HW rev. \u0026lt;042500","TP600 0762-5201/8000-0001","TP600 0762-5201/8000-0001 HW rev. \u0026lt;062500","TP600 0762-5203/8000-0001","TP600 0762-5203/8000-0001 HW rev. \u0026lt;062500","TP600 0762-5204/8000-0001","TP600 0762-5204/8000-0001 HW rev. \u0026lt;052500","TP600 0762-5205/8000-0001","TP600 0762-5205/8000-0001 HW rev. \u0026lt;032500","TP600 0762-5206/8000-0001","TP600 0762-5206/8000-0001 HW rev. \u0026lt;042500"],"published":"2025-09-15","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-09-15","vendors":["WAGO"]},"summary":"An unauthenticated remote attacker can bypass network segmentation during device boot due to undefined switch state, requiring firmware updates for WAGO CC100 switches.","url":"https://insights.sbomify.com/CVE-2025-41713/"}