{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2025-42878 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-42878 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-42878 is a high-severity vulnerability in SAP_SE SAP Web Dispatcher and Internet Communication Manager (ICM), published on 9 Dec 2025. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2025-42878 and fix it if it is affected.\n\nWhat it is: CVE-2025-42878 is a high-severity vulnerability in SAP_SE SAP Web Dispatcher and Internet Communication Manager (ICM), published on 9 Dec 2025. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2025-42878 in the wild and no public exploit code.\n\nAffected product: SAP_SE SAP Web Dispatcher and Internet Communication Manager (ICM). No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-42878/ (Markdown: https://insights.sbomify.com/CVE-2025-42878/index.md)","id":"CVE-2025-42878","markdown":"https://insights.sbomify.com/CVE-2025-42878/index.md","name":"CVE-2025-42878","record":{"aliases":["GHSA-549v-r8j8-4rmh"],"analysis":{"component_type":"server_software","fix_type":"configuration_change","impacts":["data_read","denial_of_service"],"network_reachable":"yes","non_default_config":true,"product_category":"SAP Web Dispatcher","requires_auth":"none","summary":"Unauthenticated attackers can access internal testing interfaces to expose diagnostics and disrupt services if these features are enabled.","user_interaction":"required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"sap","cpe":[],"cvss":{"score":8.2,"severity":"high","source":"cna","vector":"CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:L/A:H","version":"3.1"},"cwes":[{"id":"CWE-1244","name":"Internal Asset Exposed to Unsafe Debug Access Level or State"}],"description":"SAP Web Dispatcher and ICM may expose internal testing interfaces that are not intended for production. If enabled, unauthenticated attackers could exploit them to access diagnostics, send crafted requests, or disrupt services. This vulnerability has a high impact on confidentiality, availability and low impact on integrity and of the application.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Sensitive Data Exposure in SAP Web Dispatcher and Internet Communication Manager (ICM)","id":"CVE-2025-42878","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2025"},"n_packages":0,"n_references":2,"next":{"headline":"Code Injection vulnerability in SAP Solution Manager","id":"CVE-2025-42880"},"packages":[],"prev":{"headline":"Memory Corruption vulnerability in SAP Web Dispatcher, Internet Communication Manager and SAP Content Server","id":"CVE-2025-42877"},"products":["SAP Web Dispatcher and Internet Communication Manager (ICM)"],"published":"2025-12-09","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-12-09","vendors":["SAP_SE"]},"summary":"Unauthenticated attackers can access internal testing interfaces to expose diagnostics and disrupt services if these features are enabled.","url":"https://insights.sbomify.com/CVE-2025-42878/"}