{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2025-48017 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-48017 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-48017 is a critical path traversal vulnerability in Schweitzer Engineering Laboratories SEL-5056 Software-Defined Network Flow Controller, published on 20 May 2025. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-48017 and fix it if it is affected.\n\nWhat it is: CVE-2025-48017 is a critical path traversal vulnerability in Schweitzer Engineering Laboratories SEL-5056 Software-Defined Network Flow Controller, published on 20 May 2025. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2025-48017 in the wild and no public exploit code.\n\nAffected product: Schweitzer Engineering Laboratories SEL-5056 Software-Defined Network Flow Controller. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-48017/ (Markdown: https://insights.sbomify.com/CVE-2025-48017/index.md)","id":"CVE-2025-48017","markdown":"https://insights.sbomify.com/CVE-2025-48017/index.md","name":"CVE-2025-48017","record":{"aliases":["GHSA-m57c-xh3v-q656"],"analysis":{"component_type":"network_device","fix_type":"patch","impacts":["data_modify"],"network_reachable":"yes","non_default_config":false,"product_category":"SEL network controller","requires_auth":"none","summary":"Attackers can exploit path traversal in SEL-5056 to modify and upload files, compromising the network flow controller.","user_interaction":"not_required","vuln_class":"path_traversal"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"SEL","cpe":[],"cvss":{"score":9,"severity":"critical","source":"cna","vector":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-22","name":"Improper Limitation of a Pathname to a Restricted Directory"}],"description":"Improper limitation of pathname in Circuit Provisioning and File Import applications allows modification and uploading of files","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Improper Limitation of a Pathname to a Restricted Directory","id":"CVE-2025-48017","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"path_traversal","year":"2025"},"n_packages":0,"n_references":1,"next":{"headline":"Deserialization of Untrusted Data","id":"CVE-2025-48018"},"packages":[],"prev":{"headline":"Improper Control of Interaction Frequency","id":"CVE-2025-48016"},"products":["SEL-5056 Software-Defined Network Flow Controller"],"published":"2025-05-20","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-05-20","vendors":["Schweitzer Engineering Laboratories"]},"summary":"Attackers can exploit path traversal in SEL-5056 to modify and upload files, compromising the network flow controller.","url":"https://insights.sbomify.com/CVE-2025-48017/"}