{"answers":{"affected":"It affects 1 product.","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2025-4901 exists.","fix":"No fix has been published for CVE-2025-4901 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-4901 is a medium-severity vulnerability in D-Link DI-7003GV2, published on 18 May 2025. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-4901 and fix it if it is affected.\n\nWhat it is: CVE-2025-4901 is a medium-severity vulnerability in D-Link DI-7003GV2, published on 18 May 2025. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2025-4901 exists.\n\nAffected product: D-Link DI-7003GV2. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-4901/ (Markdown: https://insights.sbomify.com/CVE-2025-4901/index.md)","id":"CVE-2025-4901","markdown":"https://insights.sbomify.com/CVE-2025-4901/index.md","name":"CVE-2025-4901","record":{"aliases":["GHSA-4v3f-4r92-c6v3"],"analysis":{"component_type":"network_device","fix_type":"no_fix_stated","impacts":["data_read"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"D-Link router","requires_auth":"none","summary":"An attacker on the local network can access sensitive information via the HTTP endpoint state_view.data in D-Link DI-7003GV2 routers.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulDB","cpe":[{"product":"di-7003g_firmware","vendor":"dlink"}],"cvss":{"score":5.3,"severity":"medium","source":"cna","vector":"CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-284","name":"Improper Access Control"},{"id":"CWE-200","name":"Exposure of Sensitive Information to an Unauthorized Actor"}],"description":"A vulnerability classified as problematic was found in D-Link DI-7003GV2 24.04.18D1 R(68125). Affected by this vulnerability is the function sub_41E304 of the file /H5/state_view.data of the component HTTP Endpoint. The manipulation leads to information disclosure. The attack can only be done within the local network. The exploit has been disclosed to the public and may be used.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"weaponised"},"has_fix":null,"headline":"D-Link DI-7003GV2 HTTP Endpoint state_view.data sub_41E304 information disclosure","id":"CVE-2025-4901","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2025"},"n_packages":0,"n_references":5,"next":{"headline":"D-Link DI-7003GV2 versionupdate.data sub_48F4F0 information disclosure","id":"CVE-2025-4902"},"packages":[],"prev":{"headline":"Campcodes Sales and Inventory System payment.php sql injection","id":"CVE-2025-4900"},"products":["DI-7003GV2"],"published":"2025-05-18","related":[{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2023-45572","kev_date_added":null,"published":"2023-10-16"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2023-45573","kev_date_added":null,"published":"2023-10-16"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2023-45574","kev_date_added":null,"published":"2023-10-16"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2023-45575","kev_date_added":null,"published":"2023-10-16"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2023-45576","kev_date_added":null,"published":"2023-10-16"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2023-45577","kev_date_added":null,"published":"2023-10-16"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2023-45578","kev_date_added":null,"published":"2023-10-16"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"poc","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-05-19","vendors":["D-Link"]},"summary":"An attacker on the local network can access sensitive information via the HTTP endpoint state_view.data in D-Link DI-7003GV2 routers.","url":"https://insights.sbomify.com/CVE-2025-4901/"}