{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2025-49849 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-49849 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-49849 is a high-severity memory corruption vulnerability in LS Electric GMWin 4, published on 17 Jun 2025. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2025-49849 and fix it if it is affected.\n\nWhat it is: CVE-2025-49849 is a high-severity memory corruption vulnerability in LS Electric GMWin 4, published on 17 Jun 2025. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2025-49849 in the wild and no public exploit code.\n\nAffected product: LS Electric GMWin 4. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-49849/ (Markdown: https://insights.sbomify.com/CVE-2025-49849/index.md)","id":"CVE-2025-49849","markdown":"https://insights.sbomify.com/CVE-2025-49849/index.md","name":"CVE-2025-49849","record":{"aliases":["GHSA-4m5h-4vp6-7rqv"],"analysis":{"component_type":"ics_ot","fix_type":"no_fix_stated","impacts":["code_execution","denial_of_service"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"ICS HMI software","requires_auth":"none","summary":"An out-of-bounds read in LS Electric GMWin 4 allows attackers to cause memory corruption and potential code execution via malicious PRJ files.","user_interaction":"required","vuln_class":"memory_corruption"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[],"cvss":{"score":8.4,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-125","name":"Out-of-bounds Read"}],"description":"An Out-of-bounds Read vulnerability exists within the parsing of PRJ files. The issues result from the lack of proper validation of user-supplied data, which can result in different memory corruption issues within the application, such as reading and writing past the end of allocated data structures.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Out-of-bounds Read in Write in LS Electric GMWin 4","id":"CVE-2025-49849","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"memory_corruption","year":"2025"},"n_packages":0,"n_references":1,"next":{"headline":"Out-of-bounds Read in Write in LS Electric GMWin 4","id":"CVE-2025-49850"},"packages":[],"prev":{"headline":"Out-of-bounds Write in LS Electric GMWin 4","id":"CVE-2025-49848"},"products":["GMWin 4"],"published":"2025-06-17","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-06-17","vendors":["LS Electric"]},"summary":"An out-of-bounds read in LS Electric GMWin 4 allows attackers to cause memory corruption and potential code execution via malicious PRJ files.","url":"https://insights.sbomify.com/CVE-2025-49849/"}