{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2025-52457 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-52457 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-52457 is a medium-severity vulnerability in Gallagher HBUS Devices, published on 18 Nov 2025. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-52457 and fix it if it is affected.\n\nWhat it is: CVE-2025-52457 is a medium-severity vulnerability in Gallagher HBUS Devices, published on 18 Nov 2025. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2025-52457 in the wild and no public exploit code.\n\nAffected product: Gallagher HBUS Devices. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-52457/ (Markdown: https://insights.sbomify.com/CVE-2025-52457/index.md)","id":"CVE-2025-52457","markdown":"https://insights.sbomify.com/CVE-2025-52457/index.md","name":"CVE-2025-52457","record":{"aliases":["GHSA-46hf-65mw-6fg3"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["data_read","security_bypass"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Gallagher Command Centre","requires_auth":"none","summary":"An attacker with physical access can extract device-specific keys via timing discrepancies, compromising site security in Gallagher Command Centre systems.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"Gallagher","cpe":[],"cvss":{"score":5.7,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:P/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N","version":"3.1"},"cwes":[{"id":"CWE-208","name":"Observable Timing Discrepancy"}],"description":"Observable Timing Discrepancy (CWE-208) in HBUS devices may allow an attacker with physical access to the device to extract device-specific keys, potentially compromising further site security. \n\nThis issue affects Command Centre Server:\n\n9.30 prior to vCR9.30.251028a (distributed in 9.30.2881 (MR3)), 9.20 prior to vCR9.20.251028a (distributed in 9.20.3265 (MR5)), 9.10 prior to vCR9.10.251028a (distributed in 9.10.4135 (MR8)), all versions of 9.00 and prior.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Information disclosure in HBUS Devices","id":"CVE-2025-52457","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2025"},"n_packages":0,"n_references":1,"next":{"headline":"arkcompiler_ets_runtime has an out-of-bounds write vulnerability","id":"CVE-2025-52458"},"packages":[],"prev":{"headline":"Integer overflow in SAIL Image Decoding Library","id":"CVE-2025-52456"},"products":["HBUS Devices"],"published":"2025-11-18","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-11-19","vendors":["Gallagher"]},"summary":"An attacker with physical access can extract device-specific keys via timing discrepancies, compromising site security in Gallagher Command Centre systems.","url":"https://insights.sbomify.com/CVE-2025-52457/"}