{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2025-52873 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-52873 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-52873 is a high-severity missing authorization vulnerability in Cognex In-Sight 2000 series, published on 18 Sep 2025. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-52873 and fix it if it is affected.\n\nWhat it is: CVE-2025-52873 is a high-severity missing authorization vulnerability in Cognex In-Sight 2000 series, published on 18 Sep 2025. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2025-52873 in the wild and no public exploit code.\n\nAffected product: Cognex In-Sight 2000 series. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-52873/ (Markdown: https://insights.sbomify.com/CVE-2025-52873/index.md)","id":"CVE-2025-52873","markdown":"https://insights.sbomify.com/CVE-2025-52873/index.md","name":"CVE-2025-52873","record":{"aliases":["GHSA-922x-wpjc-grx8"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["data_modify","security_bypass"],"network_reachable":"yes","non_default_config":false,"product_category":"Cognex In-Sight camera","requires_auth":"low_privilege","summary":"A user with protected privileges can modify critical device settings via telnet, bypassing intended security restrictions in Cognex In-Sight cameras.","user_interaction":"not_required","vuln_class":"missing_authorization"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[],"cvss":{"score":7.2,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-732","name":"Incorrect Permission Assignment for Critical Resource"}],"description":"Cognex In-Sight Explorer and In-Sight Camera Firmware expose \na telnet-based service on port 23 to allow management operations such as\n firmware upgrades and device reboots, which require authentication. A \nuser with protected privileges can successfully invoke the \nSetSystemConfig functionality to modify relevant device properties (such\n as network settings), contradicting the security model proposed in the \nuser manual.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Cognex In-Sight Explorer and In-Sight Camera Firmware Incorrect Permission Assignment for Critical Resource","id":"CVE-2025-52873","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"missing_authorization","year":"2025"},"n_packages":0,"n_references":1,"next":{"headline":"Cross-site scripting in TeamCity","id":"CVE-2025-52875"},"packages":[],"prev":{"headline":"QTS, QuTS hero","id":"CVE-2025-52872"},"products":["In-Sight 2000 series","In-Sight 7000 series","In-Sight 8000 series","In-Sight 9000 series","In-Sight Explorer"],"published":"2025-09-18","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-09-19","vendors":["Cognex"]},"summary":"A user with protected privileges can modify critical device settings via telnet, bypassing intended security restrictions in Cognex In-Sight cameras.","url":"https://insights.sbomify.com/CVE-2025-52873/"}