{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2025-5296 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-5296 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-5296 is a high-severity path traversal vulnerability in Schneider Electric SESU, published on 18 Aug 2025. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-5296 and fix it if it is affected.\n\nWhat it is: CVE-2025-5296 is a high-severity path traversal vulnerability in Schneider Electric SESU, published on 18 Aug 2025. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2025-5296 in the wild and no public exploit code.\n\nAffected product: Schneider Electric SESU. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-5296/ (Markdown: https://insights.sbomify.com/CVE-2025-5296/index.md)","id":"CVE-2025-5296","markdown":"https://insights.sbomify.com/CVE-2025-5296/index.md","name":"CVE-2025-5296","record":{"aliases":["GHSA-8wcv-4h46-66mg"],"analysis":{"component_type":"desktop_application","fix_type":"patch","impacts":["privilege_escalation","data_modify"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Schneider Electric SESU","requires_auth":"low_privilege","summary":"A low-privileged attacker can exploit improper link resolution to write arbitrary data to protected locations, leading to privilege escalation or file corruption.","user_interaction":"not_required","vuln_class":"path_traversal"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"schneider","cpe":[],"cvss":{"score":7,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:L/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-59","name":"Improper Link Resolution Before File Access"}],"description":"CWE-59: Improper Link Resolution Before File Access ('Link Following') vulnerability exists that could cause \narbitrary data to be written to protected locations, potentially leading to escalation of privilege, arbitrary file \ncorruption, exposure of application and system information or persistent denial of service when a low-privileged \nattacker tampers with the installation folder.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Path traversal in SESU","id":"CVE-2025-5296","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"path_traversal","year":"2025"},"n_packages":0,"n_references":1,"next":{"headline":"SourceCodester Computer Store System main.c Add stack-based overflow","id":"CVE-2025-5297"},"packages":[],"prev":{"headline":"FreeFloat FTP Server PORT Command buffer overflow","id":"CVE-2025-5295"},"products":["SESU"],"published":"2025-08-18","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-08-18","vendors":["Schneider Electric"]},"summary":"A low-privileged attacker can exploit improper link resolution to write arbitrary data to protected locations, leading to privilege escalation or file corruption.","url":"https://insights.sbomify.com/CVE-2025-5296/"}