{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2025-53758 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-53758 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-53758 is a medium-severity vulnerability in Digisol XPON ONU Wi-Fi Router (DG-GR6821AC), published on 16 Jul 2025. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-53758 and fix it if it is affected.\n\nWhat it is: CVE-2025-53758 is a medium-severity vulnerability in Digisol XPON ONU Wi-Fi Router (DG-GR6821AC), published on 16 Jul 2025. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2025-53758 in the wild and no public exploit code.\n\nAffected product: Digisol XPON ONU Wi-Fi Router (DG-GR6821AC). No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-53758/ (Markdown: https://insights.sbomify.com/CVE-2025-53758/index.md)","id":"CVE-2025-53758","markdown":"https://insights.sbomify.com/CVE-2025-53758/index.md","name":"CVE-2025-53758","record":{"aliases":["GHSA-vj9q-gw7f-j56j"],"analysis":{"component_type":"network_device","fix_type":"no_fix_stated","impacts":["account_takeover"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Wi-Fi router","requires_auth":"none","summary":"An attacker with physical access can extract firmware to obtain hardcoded default admin credentials, gaining unauthorized access to the router.","user_interaction":"not_required","vuln_class":"hardcoded_credentials"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"CERT-In","cpe":[],"cvss":{"score":5.1,"severity":"medium","source":"cna","vector":"CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-312","name":"Cleartext Storage of Sensitive Information"}],"description":"This vulnerability exists in Digisol DG-GR6821AC Router due to use of default admin credentials at its web management interface. An attacker with physical access could exploit this vulnerability by extracting the firmware and reverse engineer the binary data to access the hardcoded default credentials stored in the firmware of the targeted device.\n\nSuccessful exploitation of this vulnerability could allow the attacker to gain unauthorized access to the targeted device.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Default Credential Vulnerability in Digisol DG-GR6821AC Router","id":"CVE-2025-53758","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"hardcoded_credentials","year":"2025"},"n_packages":0,"n_references":1,"next":{"headline":"Microsoft Excel Remote Code Execution Vulnerability","id":"CVE-2025-53759"},"packages":[],"prev":{"headline":"Insecure Cookie Flags Vulnerability in Digisol DG-GR6821AC Router","id":"CVE-2025-53757"},"products":["XPON ONU Wi-Fi Router (DG-GR6821AC)"],"published":"2025-07-16","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-07-16","vendors":["Digisol"]},"summary":"An attacker with physical access can extract firmware to obtain hardcoded default admin credentials, gaining unauthorized access to the router.","url":"https://insights.sbomify.com/CVE-2025-53758/"}