{"answers":{"affected":"It affects 6 products.","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2025-5447 exists.","fix":"No fix has been published for CVE-2025-5447 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-5447 is a medium-severity command injection vulnerability in Linksys Re6250 Firmware, published on 2 Jun 2025. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-5447 and fix it if it is affected.\n\nWhat it is: CVE-2025-5447 is a medium-severity command injection vulnerability in Linksys Re6250 Firmware, published on 2 Jun 2025. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2025-5447 exists.\n\nAffected product: Linksys Re6250 Firmware. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-5447/ (Markdown: https://insights.sbomify.com/CVE-2025-5447/index.md)","id":"CVE-2025-5447","markdown":"https://insights.sbomify.com/CVE-2025-5447/index.md","name":"CVE-2025-5447","record":{"aliases":["GHSA-jh65-hfwx-3vmm"],"analysis":{"component_type":"network_device","fix_type":"no_fix_stated","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"Linksys Wi-Fi Range Extender","requires_auth":"low_privilege","summary":"Remote attackers can execute arbitrary OS commands on Linksys range extenders via the ssid1MACFilter interface, posing a critical security risk.","user_interaction":"not_required","vuln_class":"command_injection"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulDB","cpe":[{"product":"re6250_firmware","vendor":"linksys"},{"product":"re6300_firmware","vendor":"linksys"},{"product":"re6350_firmware","vendor":"linksys"},{"product":"re6500_firmware","vendor":"linksys"},{"product":"re7000_firmware","vendor":"linksys"},{"product":"re9000_firmware","vendor":"linksys"}],"cvss":{"score":5.3,"severity":"medium","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-78","name":"Improper Neutralization of Special Elements used in an OS Command"},{"id":"CWE-77","name":"Improper Neutralization of Special Elements used in a Command"}],"description":"A vulnerability was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. It has been declared as critical. This vulnerability affects the function ssid1MACFilter of the file /goform/ssid1MACFilter. The manipulation of the argument apselect_%d/newap_text_%d leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"weaponised"},"has_fix":null,"headline":"Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 ssid1MACFilter os command injection","id":"CVE-2025-5447","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":"linksys:re6250_firmware","products":["linksys:re6250_firmware","linksys:re6300_firmware","linksys:re6350_firmware","linksys:re6500_firmware","linksys:re7000_firmware","linksys:re9000_firmware"],"type":"command_injection","year":"2025"},"n_packages":0,"n_references":5,"next":{"headline":"This CVE id was assigned but later discarded.","id":"CVE-2025-5448"},"packages":[],"prev":{"headline":"Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 RP_checkCredentialsByBBS os command injection","id":"CVE-2025-5446"},"products":["RE6250","RE6300","RE6350","RE6500","RE7000","RE9000"],"published":"2025-06-02","related":[{"cvss_score":8.7,"headline":"Memory corruption in RE6250","id":"CVE-2025-14133","kev_date_added":null,"published":"2025-12-06"},{"cvss_score":8.7,"headline":"Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 mod_form.so stack-based overflow","id":"CVE-2025-14134","kev_date_added":null,"published":"2025-12-06"},{"cvss_score":8.7,"headline":"Memory corruption in RE6250","id":"CVE-2025-14135","kev_date_added":null,"published":"2025-12-06"},{"cvss_score":8.7,"headline":"Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 mod_form.so stack-based overflow","id":"CVE-2025-14136","kev_date_added":null,"published":"2025-12-06"},{"cvss_score":8.7,"headline":"Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 setIpv6 stack-based overflow","id":"CVE-2025-9481","kev_date_added":null,"published":"2025-08-26"},{"cvss_score":8.7,"headline":"Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 portRangeForwardAdd stack-based overflow","id":"CVE-2025-9482","kev_date_added":null,"published":"2025-08-26"},{"cvss_score":8.7,"headline":"Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 singlePortForwardAdd stack-based overflow","id":"CVE-2025-9483","kev_date_added":null,"published":"2025-08-26"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"poc","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-06-02","vendors":["Linksys"]},"summary":"Remote attackers can execute arbitrary OS commands on Linksys range extenders via the ssid1MACFilter interface, posing a critical security risk.","url":"https://insights.sbomify.com/CVE-2025-5447/"}