CVE-2025-54497 Cognex In-Sight Explorer and In-Sight Camera Firmware Incorrect Permission Assignment for Critical Resource

High 7.2 Published Updated

Authenticated users can modify serial port settings on Cognex In-Sight cameras, violating the intended security model and allowing unauthorized device configuration changes.

Exploited in the wild
Not known
Login needed
Any signed-in user
Attackable
Over the internet
Victim action needed
Not needed
Fix
None listed

What is CVE-2025-54497?

CVE-2025-54497 is a high-severity missing authorization vulnerability in Cognex In-Sight 2000 series, published on 18 Sep 2025. Any signed-in user can exploit it over the network, with no action from the victim.

Official description

Cognex In-Sight Explorer and In-Sight Camera Firmware expose a telnet-based service on port 23 to allow management operations such as firmware upgrades and device reboots, which require authentication. A user with protected privileges can successfully invoke the SetSerialPort functionality to modify relevant device properties (such as serial interface settings), contradicting the security model proposed in the user manual.

Weakness: CWE-732

Which versions are affected by CVE-2025-54497?

How do I fix CVE-2025-54497?

No fix has been published for CVE-2025-54497 yet. Limit exposure of the affected software until one is available.

Upgrade, and check permissions on every request on the server, not only in the interface. More about Missing authorization.

Is CVE-2025-54497 being exploited?

There is no known exploitation of CVE-2025-54497 in the wild and no public exploit code.

Sources

Also known as GHSA-2mwg-fg86-hrm4.

Is CVE-2025-54497 in your software?

Upload an SBOM and sbomify checks it against every vulnerability here, every day.

Check your SBOMs for free