{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2025-54497 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-54497 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-54497 is a high-severity missing authorization vulnerability in Cognex In-Sight 2000 series, published on 18 Sep 2025. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-54497 and fix it if it is affected.\n\nWhat it is: CVE-2025-54497 is a high-severity missing authorization vulnerability in Cognex In-Sight 2000 series, published on 18 Sep 2025. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2025-54497 in the wild and no public exploit code.\n\nAffected product: Cognex In-Sight 2000 series. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-54497/ (Markdown: https://insights.sbomify.com/CVE-2025-54497/index.md)","id":"CVE-2025-54497","markdown":"https://insights.sbomify.com/CVE-2025-54497/index.md","name":"CVE-2025-54497","record":{"aliases":["GHSA-2mwg-fg86-hrm4"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["data_modify","security_bypass"],"network_reachable":"yes","non_default_config":false,"product_category":"Machine vision camera","requires_auth":"low_privilege","summary":"Authenticated users can modify serial port settings on Cognex In-Sight cameras, violating the intended security model and allowing unauthorized device configuration changes.","user_interaction":"not_required","vuln_class":"missing_authorization"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[],"cvss":{"score":7.2,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-732","name":"Incorrect Permission Assignment for Critical Resource"}],"description":"Cognex In-Sight Explorer and In-Sight Camera Firmware expose \na telnet-based service \non port 23 to allow management operations such as firmware upgrades and \ndevice reboots, which require authentication. A user with protected \nprivileges can successfully invoke the SetSerialPort functionality to \nmodify relevant device properties (such as serial interface settings), \ncontradicting the security model proposed in the user manual.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Cognex In-Sight Explorer and In-Sight Camera Firmware Incorrect Permission Assignment for Critical Resource","id":"CVE-2025-54497","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"missing_authorization","year":"2025"},"n_packages":0,"n_references":1,"next":{"headline":"Insecure string comparison enables timing attacks","id":"CVE-2025-54499"},"packages":[],"prev":{"headline":"Fuji Electric Monitouch V-SFT-6 Heap-based Buffer Overflow","id":"CVE-2025-54496"},"products":["In-Sight 2000 series","In-Sight 7000 series","In-Sight 8000 series","In-Sight 9000 series","In-Sight Explorer"],"published":"2025-09-18","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-09-19","vendors":["Cognex"]},"summary":"Authenticated users can modify serial port settings on Cognex In-Sight cameras, violating the intended security model and allowing unauthorized device configuration changes.","url":"https://insights.sbomify.com/CVE-2025-54497/"}