{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2025-54926 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-54926 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-54926 is a high-severity path traversal vulnerability in Schneider Electric EcoStruxure™ Power Monitoring Expert (PME), published on 20 Aug 2025. An attacker needs administrator access to exploit it, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-54926 and fix it if it is affected.\n\nWhat it is: CVE-2025-54926 is a high-severity path traversal vulnerability in Schneider Electric EcoStruxure™ Power Monitoring Expert (PME), published on 20 Aug 2025. An attacker needs administrator access to exploit it, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2025-54926 in the wild and no public exploit code.\n\nAffected product: Schneider Electric EcoStruxure™ Power Monitoring Expert (PME). No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-54926/ (Markdown: https://insights.sbomify.com/CVE-2025-54926/index.md)","id":"CVE-2025-54926","markdown":"https://insights.sbomify.com/CVE-2025-54926/index.md","name":"CVE-2025-54926","record":{"aliases":["GHSA-9q86-673r-39p8"],"analysis":{"component_type":"web_application","fix_type":"patch","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"Power Monitoring Expert","requires_auth":"high_privilege","summary":"An authenticated admin can achieve remote code execution via path traversal in file uploads on Schneider Electric power monitoring software.","user_interaction":"not_required","vuln_class":"path_traversal"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"schneider","cpe":[],"cvss":{"score":7.2,"severity":"high","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-22","name":"Improper Limitation of a Pathname to a Restricted Directory"}],"description":"CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause remote code execution when an authenticated attacker with admin privileges uploads a malicious file over HTTP which then gets executed.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Path traversal in EcoStruxure™ Power Monitoring Expert (PME)","id":"CVE-2025-54926","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"path_traversal","year":"2025"},"n_packages":0,"n_references":1,"next":{"headline":"Path traversal in EcoStruxure™ Power Monitoring Expert (PME)","id":"CVE-2025-54927"},"packages":[],"prev":{"headline":"Server-side request forgery in EcoStruxure™ Power Monitoring Expert (PME)","id":"CVE-2025-54925"},"products":["EcoStruxure™ Power Monitoring Expert (PME)","EcoStruxure™ Power Operation (EPO) Advanced Reporting and Dashboards Module"],"published":"2025-08-20","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-08-20","vendors":["Schneider Electric"]},"summary":"An authenticated admin can achieve remote code execution via path traversal in file uploads on Schneider Electric power monitoring software.","url":"https://insights.sbomify.com/CVE-2025-54926/"}