{"answers":{"affected":"It affects 1 product.","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2025-5571 exists.","fix":"No fix has been published for CVE-2025-5571 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-5571 is a medium-severity command injection vulnerability in D-Link DCS-932L, published on 4 Jun 2025. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-5571 and fix it if it is affected.\n\nWhat it is: CVE-2025-5571 is a medium-severity command injection vulnerability in D-Link DCS-932L, published on 4 Jun 2025. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2025-5571 exists.\n\nAffected product: D-Link DCS-932L. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-5571/ (Markdown: https://insights.sbomify.com/CVE-2025-5571/index.md)","id":"CVE-2025-5571","markdown":"https://insights.sbomify.com/CVE-2025-5571/index.md","name":"CVE-2025-5571","record":{"aliases":["GHSA-hwf5-vv36-8f29"],"analysis":{"component_type":"iot_embedded","fix_type":"end_of_life","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"D-Link IP camera","requires_auth":"low_privilege","summary":"Remote attackers can execute arbitrary OS commands via the AdminID parameter in the setSystemAdmin function of unsupported D-Link cameras.","user_interaction":"not_required","vuln_class":"command_injection"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulDB","cpe":[{"product":"dcs-932l_firmware","vendor":"dlink"}],"cvss":{"score":5.3,"severity":"medium","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-78","name":"Improper Neutralization of Special Elements used in an OS Command"},{"id":"CWE-77","name":"Improper Neutralization of Special Elements used in a Command"}],"description":"A vulnerability was found in D-Link DCS-932L 2.18.01. It has been classified as critical. Affected is the function setSystemAdmin of the file /setSystemAdmin. The manipulation of the argument AdminID leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"weaponised"},"has_fix":null,"headline":"D-Link DCS-932L setSystemAdmin os command injection","id":"CVE-2025-5571","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"command_injection","year":"2025"},"n_packages":0,"n_references":5,"next":{"headline":"D-Link DCS-932L setSystemEmail stack-based overflow","id":"CVE-2025-5572"},"packages":[],"prev":{"headline":"Cross-site scripting in AI Engine – The Chatbot, AI Framework \u0026 MCP for WordPress","id":"CVE-2025-5570"},"products":["DCS-932L"],"published":"2025-06-04","related":[{"cvss_score":8.7,"headline":"D-Link DCS-932L setSystemEmail stack-based overflow","id":"CVE-2025-5572","kev_date_added":null,"published":"2025-06-04"},{"cvss_score":8.7,"headline":"D-Link DCS-932L gpio sub_404780 stack-based overflow","id":"CVE-2025-4841","kev_date_added":null,"published":"2025-05-17"},{"cvss_score":8.7,"headline":"D-Link DCS-932L ucp isUCPCameraNameChanged stack-based overflow","id":"CVE-2025-4842","kev_date_added":null,"published":"2025-05-17"},{"cvss_score":8.7,"headline":"D-Link DCS-932L udev SubUPnPCSInit stack-based overflow","id":"CVE-2025-4843","kev_date_added":null,"published":"2025-05-17"},{"cvss_score":7.3,"headline":"Command injection in n/a","id":"CVE-2026-36983","kev_date_added":null,"published":"2026-05-11"},{"cvss_score":6.5,"headline":"Denial of service in n/a","id":"CVE-2024-37606","kev_date_added":null,"published":"2024-12-17"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"poc","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-06-04","vendors":["D-Link"]},"summary":"Remote attackers can execute arbitrary OS commands via the AdminID parameter in the setSystemAdmin function of unsupported D-Link cameras.","url":"https://insights.sbomify.com/CVE-2025-5571/"}